TR3-GL541-1_1E.pdf.pdf - 第46页

3.1 Proper Data Listing The Proper data is a list of machine calibration variables and initialization parameters used to compensate the subtle differences between machines. Whether physically different or the way the mac…

100%1 / 74
Chapter 3
Proper Data
3.1 Proper Data Listing
The Proper data is a list of machine calibration variables and initialization
parameters used to compensate the subtle differences between machines.
Whether physically different or the way the machines are used in production,
these values can seriously affect the performance of a machine if altered
improperly.
After altering any of the Proper data items, a printed copy of the new Proper data
file should be placed in the machine’s Control Box. A plastic folder to hold this
copy is mounted to the right hand door of Control Box 2 for this purpose. Do not
forget to write the date, the machine’s serial number and your initials at the top of
the printout. Also, always keep the previous copy. This will be useful if a
problem should occur. We highly recommend that you also make a copy of the
Proper file to a floppy disk. Save it with a name that includes the machine’s serial
number and the date.
The Proper data items are classified according to the following symbols.
%: Varies from machine to machine. Proper data must be measured.
*: Cannot be changed by the user.
#: Can be changed by the user.
@: Automatically set by the machine (or it may be changed by the user.)
$: Not currently in use.
Warning
The Proper data should never be altered without the use of this manual
or without contacting a Fuji technical support engineer. Altering the
Proper data items incorrectly will damage the machine.
WN003
Chapter 3 3.1 Proper Data Listing
Edition 1.0 3-1 GL-541E Level 3 Reference
The meaning of each Proper data item is described later in this section. Please
refer to this section when setting Proper data on GL-541E machines.
No. Name Range
# 1: MG4ID ID_Code =
# 2: MG4LG Language = 0
# 3: MG4REL Red_Light = 1024
# 4: MG4YEL Yellow_Light = 16420
# 5: MG4BLL Blue_Light = 768
# 6: MG4REB Red_Flash = 8
# 7: MG4YEB Yellow_Flash = 8210
# 8: MG4BLB Blue_Flash = 2241
$ 9: MG4USDA User_Define_A = 0
$ 10: MG4S1 spare = 0
# 11: MG4MASA Machine_Status_A = 0
# 12: MG4MASB Machine_Status_B = 0
# 13: MG4MAID Machine_ID = 0
# 14: MG4PCBL PCB_Location = 0
$ 15: MG4RCTM Recovery_Times = 0
$ 16: MG4S2 spare = 0
$ 17: MG4S3 spare = 0
$ 18: MG4S4 spare = 0
$ 19: MG4S5 spare = 0
# 20: MG4LOSA Loader_Status_A = 0
# 21. MG4LOSB Loader_Status_B = 0
# 22: MG4CVT Conveyor_Type = 0
# 23: MG4WASG Wait_Signal = 0
# 24: MG4BUI Busy_Invalid = 0
# 25: MG4CVC Conveyor_Control = 0
# 26: MG4CVAL Conveyor_Adj_Limit = 50
# 27: MG4CVSO Conveyor_Stop_Offset = 30
# 28: MG4CVAT Conveyor_adj_Timer = 60000
% 29: MG4WMAL Width_max_Limit = 46000
% 30: MG4WMIL Width_min_Limit = 5000
$ 31: MG4S6 spare = 0
$ 32: MG4S7 spare = 0
$ 33: MG4S8 spare = 0
$ 34: MG4S9 spare = 0
$ 35: MG4S10 spare = 0
Chapter 3 3.1 Proper Data Listing