00196806-01_IM_EDM_1.9_EN.pdf - 第30页

Installation Manu al SIPLACE Engine ering Data Manag er (EDM) Version 1 .9 Issue 02/2009 30 5.2.3.1 Server type Key: serverT ype Type: Enum Values: LINE MASTER BOTH CLEARINGPO OL Valid for: Line server Master server Clea…

100%1 / 65
Installation Manual SIPLACE Engineering Data Manager (EDM) Version 1.9 02/2011 Edition
29 / 65
(5.2.3.27)
templateStorage Path L;M;D Storage location for application
templates (5.2.3.23)
transceiverClass Class L;M;C;T;D Class of data transfer (5.2.3.8)
useAdvancedNotificationFiltering String
("true"/"false")
M;D Activate/deactivate direct
import/rejection of notifications in
the Master Server (5.2.3.17)
useModifiedObjectProtection String
("true"/"false")
L;D Forced overwriting of changed
objects with older master data
(5.2.3.18)
useBlobExtension String
("true"/"false")
L;M;D Activates/deactivates EDM VDM
BLOB extensions (5.2.3.32)
xmlImportVisionDataAdvancedAction Integer L;M;C;D Sets the
VisionDataAdvancedAction
property of XmlImport.
Table 7 Contents of the configuration file
Installation Manual SIPLACE Engineering Data Manager (EDM) Version 1.9 Issue 02/2009
30
5.2.3.1 Server type
Key:
serverType
Type:
Enum
Values:
LINE
MASTER
BOTH
CLEARINGPOOL
Valid for:
Line server
Master server
Clearing pool
Description:
Specifies the type of installation. The EDM server is started as a Line Server,
Master Server or hybrid depending on this setting (should only be used for test
purposes).
5.2.3.2 Help folder
Key:
helpDirectory
Type:
Path
Default:
[AppDir]\help
Valid for:
Line server
Master server
Clearing pool
EDM Tool
Description:
Folder for online documentation
Installation Manual SIPLACE Engineering Data Manager (EDM) Version 1.9 02/2011 Edition
31 / 65
5.2.3.3 Distribution list for EDM notifications
Key:
notificationDistributorClass
Type:
Class
Default:
Siemens.SiplacePro.EDM.DataExchange.EmailDistributor,
DataExchange
Valid for:
Master server
Description:
Class, i.e. implementation of the notification service. At the present, distribution via
email is available using the default value as a reference.
5.2.3.4 Configuration of EDM notification traffic
Key:
notificationDistributorConfiguratorClass
Type:
Class
Default:
Siemens.SiplacePro.EDM.UserInterface.EmailConfigurator,
UserInterface
Valid for:
Master server
Description:
Configuration dialog box for the notification service. The actual configuration of the
notification service depends on its implementation. Configuration of an email service
referenced using the default value is currently supported.