Installation Manual SIPLACE Engineering Data Manager (EDM) Version 1.9 Issue 02/2009
42
Valid for:
Line server
Master server
Description:
Activates/deactivates EDM VDM BLOB extensions. If this option is activated,
UseVdmBlobExtension from the custom configuration must not be activated.
5.2.3.33 Advanced vision data actions
Key:
xmlImportVisionDataAdvancedAction
Type:
Integer
Default:
9
Valid for:
Line server
Master server
Clearing pool
Description:
Sets the VisionDataAdvancedAction property of the XML import as a bit-encoded
value.
It is recommended that "9" is set for all EDM computers. This value should be
retained on the EDM Master and EDM Clearing Pool computers.
There are, however, two alternatives for EDM Line Servers to control the behavior
of EDM with respect to line and station BLOBs.
1. The Vision data information on the EDM Master Server and the EDM Line
Server should be kept consistent. When transferring data from the EDM Master,
line and station BLOBs changed on the EDM Line Server are replaced by the
vsersions on the Master. BLOBs that have been removed on the Master are
also deleted on the EDM Line Server.
This behavior is set with the value "1" for
xmlImportVisionDataAdvancedAction
in the configuration for the EDM Line
Server.
2. The Vision data information on the EDM Line Server should be retained. Any
change to or deletion of the line or station BLOBs on the Master is not
transferred to the Vision data on the EDM Line Server.
To achieve this, the value "9" must be retained for
xmlImportVisionDataAdvancedAction
in the configuration of the EDM Line
Server.
5.2.3.34 Customer configuration
Key:
customConfig
Type:
Section
Valid for:
Line server
Master server
Installation Manual SIPLACE Engineering Data Manager (EDM) Version 1.9 02/2011 Edition
43 / 65
Clearing pool
EDM Tool
Description:
This section contains pairs of values of the form:
<add key="[string]" value="[string]"/>
Key (default):
skipOptimisationResultsForNotifications (true)
If true: Suppresses transfer of optimization results in job notifications.
preservePcbBarcodesDuringMasterImport (true)
If true: Never overwrites the PCB barcodes in the master database with (local)
barcodes from the Line Server.
useVdmBlobExtension (false)
If true: Activates EDM BLOB handling. This option should only be activated if
this is necessary for reasons of compatibility. It is recommended that you leave
this value set to "false" and use EDM BLOB handling.
If this option is activated, EDM BLOB handling must be deactivated with the
entry <add key="UseBlobExtension" value="false"/>.
CompatibilityMode (false)
If true: Allows restricted operation of an EDM Line Server together with an EDM
1.1 Master Server.
Caution: This mode must not be used for long-term mixed operation, but only
for gradual line-by-line upgrading of the EDM system (see 4.4).
doNotUseDefaultCategoryInCommentDialog (false)
doNotUseDefaultUserInCommentDialog (false)
doNotUseDefaultCommentInCommentDialog (false)
If true: Does not enter default values into the relevant field (category, user
name or comment) when the dialog box for entering a comment for a
notification is opened. This means that the contents must be entered manually
each time.
forceUserEntryInCommentDialog (false)
forceCommentEntryInCommentDialog (false)
forceCategoryEntryInCommentDialog (false)
If true: Forces the user to make an entry in the relevant field (category, user
name or comment) in the dialog box for entering a comment for a notification.
Empty entries are no longer accepted.
EdeUserControlOverride
This class name specifies the control used in place of the Extended Difference
Editor.
CompressionHelper.ZipCompressionLevel (9)
Integer 0 through 9.
Compression rate for data transfer. Specifies the compression level of the
algorithm used. A lower compression rate can be required if memory problems
arise as a result of large volumes of data during compression.
setUserInCommentDialogTo
Installation Manual SIPLACE Engineering Data Manager (EDM) Version 1.9 Issue 02/2009
44
Possible values: "[SiplaceProUserName]", "[WindowsUserName]" or any
text.
On an EDM Client, specifies the value used to preset the "User" field in the
confirmation dialog box of the EDM Client.
disableUserEntryInCommentDialog (false)
If this option is enabled, users of the confirmation dialog box on the EDM Client
cannot change the predefined user name. The name selected in
setUserInCommentDialogTo is used.
5.2.4 Configuring push mode
Push mode provides a large number of settings that allow EDM to be tailored to the needs of the customer.
5.2.4.1 General settings
Setting Default Valid for Explanation
EnablePushMode false ALL Activates push mode. This setting must be enabled on
all EDM computers (EDM Master, EDM Client and
EDM Clearing Pool) that are to participate in push
mode.
5.2.4.2 Automatic push in the Clearing Pool
Auto Push can maintain the consistency of the data if a line engineer on an EDM Client makes changes to
an object that are rejected in the Clearing Pool. In this event, the version of the object in the EDM Master
can be automatically transferred to the line. This means that the object on the line that is invalid from the
perspective of the data preparation engineer is replaced by the copy in the Clearing Pool.
Setting Default Valid for Explanation
ClearingPool.AutomaticPush.Enabled false Clearing
pool
Activates Auto Push at the Clearing Pool.
ClearingPool.AutomaticPush.RequireConfirmation true Clearing
pool
Specifies whether the Clearing Pool should show a
confirmation dialog box on every Auto Push.
5.2.4.3 User guidance on the EDM Client
These parameters specify how the various push operations are presented to the user at the EDM Client.
Setting Default Valid for Explanation
ConfirmAtLineServer true Data Transfer
Manager
If set to "true", a confirmation dialog box is displayed
on the EDM line for the push operations to be
imported. Otherwise, the import is executed
immediately, depending on the settings described in
5.2.4.4.
If OperatorMayOverride.ConfirmAtLineServer
is enabled, this setting acts as the default value and
can be overwritten for each individual push operation in
the Data Transfer Manager.
AllowReject
false Data Transfer
Manager
Specifies whether the Line Engineer is permitted to
reject the push operation (or is forced to import pushed