00196806-01_IM_EDM_1.9_EN.pdf - 第41页

Installation Manu al SIPLACE Engine ering Data Manag er (EDM) Version 1 .9 02/2011 Edition 41 / 65 EDM Tool Description: The entr y has the form at <category valu e="categor y"/> 5.2.3.30 Request configur…

100%1 / 65
Installation Manual SIPLACE Engineering Data Manager (EDM) Version 1.9 Issue 02/2009
40
5.2.3.25 SQL database access
Key:
sqlDataSource
Type:
String
Valid for:
Master server
Clearing pool
Description:
Access to the SQL server to store the change notifications, the objects changed on
the lines and information on push mode (EDM database).
This setting does not refer to the SIPLACE Pro database.
5.2.3.26 SQL user name
Key:
sqlUserName
Type:
String
Valid for:
Master server
Clearing pool
Description:
User name for access to the SQL server.
5.2.3.27 SQL password
Key:
sqlUserPassword
Type:
String
Valid for:
Master server
Clearing pool
Description:
Encrypted password for access to the SQL server. This cannot be changed
manually in the current version.
5.2.3.28 Starting point
Key:
startingPoints
Type:
Section
Valid for:
Master server
Description:
Configures allowable starting points in the application template.
The entry has the format
<objectServerType value="ObjectServerType"/>
5.2.3.29 Comment categories
Key:
CommentCategories
Type:
Section
Valid for:
Master server
Installation Manual SIPLACE Engineering Data Manager (EDM) Version 1.9 02/2011 Edition
41 / 65
EDM Tool
Description:
The entry has the format
<category value="category"/>
5.2.3.30 Request configuration
Key:
requestCommandConfig
Type:
Section
Valid for:
Master server
Description:
This section contains pairs of values of the form:
<add key="[request]" value="[Class]"/>
There is one entry for each of the services provided by the Master Server. These
settings should only be changed by the developer since they depend on the
implementation of the Master Server, and improper settings can affect the integrity
and operation of the system as a whole.
See SDS SIPLACE EDM.
5.2.3.31 Aliases
Key:
machineAliasNames
Type:
Section
Valid for:
Line server
Master server
Clearing pool
Description:
The network ID of EDM computers is converted to an alias when it is displayed in
the EDM program components in order to make it more readable for humans. Enter
all the Line Servers in the overall EDM system in this section. This section contains
pairs of values of the form:
<add key="[string]" value="[string]"/>
The key is the network identification of an EDM computer (not an IP address, only
Windows computer names). The value can be any name different from the network
ID.
Important note: The assignment of the computer ID to the alias must be identical on
all EDM computers (Master Server, Line Server, Clearing Pool). Aliases must be
unique.
5.2.3.32 EDM VDM BLOB extensions
Key:
useVdmExtension
Type:
String
Default:
true
Installation Manual SIPLACE Engineering Data Manager (EDM) Version 1.9 Issue 02/2009
42
Valid for:
Line server
Master server
Description:
Activates/deactivates EDM VDM BLOB extensions. If this option is activated,
UseVdmBlobExtension from the custom configuration must not be activated.
5.2.3.33 Advanced vision data actions
Key:
xmlImportVisionDataAdvancedAction
Type:
Integer
Default:
9
Valid for:
Line server
Master server
Clearing pool
Description:
Sets the VisionDataAdvancedAction property of the XML import as a bit-encoded
value.
It is recommended that "9" is set for all EDM computers. This value should be
retained on the EDM Master and EDM Clearing Pool computers.
There are, however, two alternatives for EDM Line Servers to control the behavior
of EDM with respect to line and station BLOBs.
1. The Vision data information on the EDM Master Server and the EDM Line
Server should be kept consistent. When transferring data from the EDM Master,
line and station BLOBs changed on the EDM Line Server are replaced by the
vsersions on the Master. BLOBs that have been removed on the Master are
also deleted on the EDM Line Server.
This behavior is set with the value "1" for
xmlImportVisionDataAdvancedAction
in the configuration for the EDM Line
Server.
2. The Vision data information on the EDM Line Server should be retained. Any
change to or deletion of the line or station BLOBs on the Master is not
transferred to the Vision data on the EDM Line Server.
To achieve this, the value "9" must be retained for
xmlImportVisionDataAdvancedAction
in the configuration of the EDM Line
Server.
5.2.3.34 Customer configuration
Key:
customConfig
Type:
Section
Valid for:
Line server
Master server