Installation Manu al SIPLACE Engine ering Data Manag er (EDM) Version 1 .9 02/2011 Edition 51 / 65 5.3.2.2 Workflow modules 5.3.2.2.1 Basics Figure 15 sho ws all curren tly available m odules that c an be used t o form a…

100%1 / 65
Installation Manual SIPLACE Engineering Data Manager (EDM) Version 1.9 Issue 02/2009
50
</transition>
Figure 14 Default transition
Specifying "all" for the initial state causes this transition to be used for all states. The transition above
therefore defines a general timeout response. A default transition is only executed when no specific
transition is defined for the particular event. This means you can implicitly define more than one transition
for a state/event pair. However, it is not possible to describe more than one default transition for an event.
Installation Manual SIPLACE Engineering Data Manager (EDM) Version 1.9 02/2011 Edition
51 / 65
5.3.2.2 Workflow modules
5.3.2.2.1 Basics
Figure 15 shows all currently available modules that can be used to form a workflow. However, since future
requirements with respect to designing processes are difficult to assess, it was decided to follow an
implementation path which allows flexible extension and configuration.
To make reconfiguring the system on-site as easy as possible, all possible states, even those that are not
used, as well as all events and transitions are contained in the standard configuration (see Section 5.3.3).
Those transitions that must be executed (shown in the figure without a colored border) as well as those for
the standard flow (highlighted in gray in the figure) are activated. These transitions can be replaced by any
alternative found in the same level of the flow chart. To do this, the "old" transition is commented out and
the new one is commented in. If several transitions belong to a module, then all these transitions are to be
commented in or out accordingly.
An example is shown below to clarify this. The standard flow for the selected objects in the default
configuration appears as follows:
<transition name="selectIdentities" currentState="selectObjects"
event="selectIds"
class="Siemens.SiplacePro.EDM.DataExchange.Actions.Sel ectIdentitiesAction,Dat
aExchange">
…
</transition>
<!-- Pull workflow variants -->
<!-- Use fixed selection
<transition name="useIdentities" currentState="selectObjects"
event="selectIds"
class="Siemens.SiplacePro.EDM.DataExchange.Actions.UseConfiguredIdentitiesA
ction,DataExchange">
…
</transition> -->
This must now be converted to a fixed set of objects to be transferred. This means that the configuration
must be adapted as follows:
<!--
<transition name="selectIdentities" currentState="selectObjects"
event="selectIds"
class="Siemens.SiplacePro.EDM.DataExchange.Actions.SelectIdentitiesAction,Data
Exchange">
…
</transition>
-->
Installation Manual SIPLACE Engineering Data Manager (EDM) Version 1.9 Issue 02/2009
52
<!-- Use fixed selection -->
<transition name="useIdentities" currentState="selectObjects" event="selectIds"
class="Siemens.SiplacePro.EDM.DataExchange.Actions.UseConfiguredIdentitiesActi
on,DataExchange">
…
</transition>
5.3.2.2.2 Additional configuration
Some of the modules require you to specify additional settings. The affected modules are labeled
accordingly in Figure 15. The custom section of the application configuration was used to make room for
the additional configuration attributes.
The module "VDM for CS" adds the VDM Blob handling option to each application template that affects
component shapes. When this module is activated, the Vision data is also transferred for each component
shape pulled.
Module: VDM for CS
Key Form Contents
Configure VDM as described.
Table 8 Additional settings for "VDM for CS"
Module: Fixed Template
Key Form Contents
templateName String Name of the application template to
be used
Table 9 Additional settings for "fixed templates"
An example for Table 9:
<customConfig>
<add key=“templateName“ value=“All Component Shapes“/>
</customConfig>
Module: Fixed Objects
Key Form Contents
objectNames A semicolon-separated (";"), full SIPLACE Pro path.
The following generalized constructs are allowed for
the object names:
Type:* - All objects of this type
Type:Path\* - All objects of this type in this
path (not in subfolders of this
List containing the names of the
objects to be transferred.