00196806-01_IM_EDM_1.9_EN.pdf - 第32页
Installation Manu al SIPLACE Engine ering Data Manag er (EDM) Version 1 .9 Issue 02/2009 32 5.2.3.5 Notification interval Key: notificationInter val Type: Time Default: P0Y0M0DT0H 15M0S (= 15 minute s) Valid for: Line se…
Installation Manual SIPLACE Engineering Data Manager (EDM) Version 1.9 02/2011 Edition
31 / 65
5.2.3.3 Distribution list for EDM notifications
Key:
notificationDistributorClass
Type:
Class
Default:
Siemens.SiplacePro.EDM.DataExchange.EmailDistributor,
DataExchange
Valid for:
Master server
Description:
Class, i.e. implementation of the notification service. At the present, distribution via
email is available using the default value as a reference.
5.2.3.4 Configuration of EDM notification traffic
Key:
notificationDistributorConfiguratorClass
Type:
Class
Default:
Siemens.SiplacePro.EDM.UserInterface.EmailConfigurator,
UserInterface
Valid for:
Master server
Description:
Configuration dialog box for the notification service. The actual configuration of the
notification service depends on its implementation. Configuration of an email service
referenced using the default value is currently supported.
Installation Manual SIPLACE Engineering Data Manager (EDM) Version 1.9 Issue 02/2009
32
5.2.3.5 Notification interval
Key:
notificationInterval
Type:
Time
Default:
P0Y0M0DT0H15M0S (= 15 minutes)
Valid for:
Line server
Description:
Time period during which the change notifications will be collected on the Line
Servers before they are sent to the Master Server. The other options are as
follows (from left to right):
Y = years
M = months
D = days
H = hours
M = minutes
S = seconds
The period should not be shorter than 5 minutes.
5.2.3.6 Notification storage
Key:
notificationStorage
Type:
Endpoint
Default:
notificationStorage
Valid for:
Line server
Description:
Buffer for collected change notifications.
5.2.3.7 Master server
Key:
masterServer
Type:
String
Valid for:
Line server
Master server
Clearing pool
Description:
Network ID of the Master Server. Windows computer name only. IP addresses are
not permitted.
5.2.3.8 Transceiver
Key:
transceiverClass
Type:
Class
Default:
Siemens.SiplacePro.EDM.DataExchange.MsmqTransceiver,
DataExchange
Valid for:
Line server
Installation Manual SIPLACE Engineering Data Manager (EDM) Version 1.9 02/2011 Edition
33 / 65
Master server
Clearing pool
EDM Tool
Description:
Implements the data transfer between the Line Servers and Master Server. This
entry must be identical on all installed systems. The exact format of the "endpoint"
values depend on this value. The default setting uses MSMQ to transfer the data.
Endpoint:
An endpoint entry has the following format for the MSMQ transceiver:
Private$\[queue-name].
Note that private queues absolutely must be used here. Only private queues can be
used in both a domain/active directory-based network environment as well as in a
pure workgroup installation.
5.2.3.9 Outgoing requests
Key:
masterRequests
Type:
Endpoint
Valid for:
Line server
Clearing pool
Description:
Target address for service requests sent by a Line Server to the Master Server. The
setting must be identical to the "Incoming Requests" setting on the Master Server.