Installation Manu al SIPLACE Engine ering Data Manag er (EDM) Version 1 .9 02/2011 Edition 35 / 65 5.2.3.13 Incoming Clearing Pool reques ts Key: incomingCleari ngPoolRe quests Type: Endpoint Valid for: Master server Cle…
Installation Manual SIPLACE Engineering Data Manager (EDM) Version 1.9 Issue 02/2009
34
5.2.3.10 Outgoing change notifications
Key:
masterNotifications
Type:
Endpoint
Valid for:
Line server
Description:
Target address for change notifications sent by a Line Server to the Master Server.
The setting must be identical to the "incoming change notifications" setting on the
Master Server.
5.2.3.11 Incoming requests
Key:
incomingRequests
Type:
Endpoint
Valid for:
Master server
Description:
Endpoint at which the Master Server listens in for incoming service requests.
Determines the value for "outgoing requests" on the Line Servers.
The value must be different from the value for "incoming change notifications".
5.2.3.12 Incoming change notifications
Key:
incomingNotifications
Type:
Endpoint
Valid for:
Master server
Description:
Endpoint at which the Master Server listens in for incoming change notifications.
Determines the value for "outgoing change notifications" on the Line Servers.
The value must be different from the value for "incoming requests".
Installation Manual SIPLACE Engineering Data Manager (EDM) Version 1.9 02/2011 Edition
35 / 65
5.2.3.13 Incoming Clearing Pool requests
Key:
incomingClearingPoolRequests
Type:
Endpoint
Valid for:
Master server
Clearing pool
Description:
Endpoint at which the Clearing Pool listens for incoming commands from the master
service.
5.2.3.14 EDM tool endpoint
Key:
edmToolEndPoint
Type:
Endpoint
Default:
EDM_SPI_REMOTE_HOST:9002/EdmTool
Valid for:
Master server
Line server
EDM Tool
Description:
Endpoint for entering change notifications. The default value means that the
comment dialog boxes always open on the computer at which the SPI event
was triggered that caused the notification which requires a comment (if an EDM
tool is installed there).
If the line engineer is to enter the comments at a different computer, replace
EDM_SPI_REMOTE_HOST in the configuration file of the Line Server with the
host name of this computer.
5.2.3.15 Endpoint configuration
Key:
endpointConfig
Type:
Section
Valid for:
Master server
Description:
This section contains pairs of values of the form:
<add key="[hostname]" value="[Endpoint]"/>
There is one pair of such values for each Line Server. This list describes the
connections from the Master Server to the Line Servers to be used.
The network ID (not the alias) of the computer concerned must be entered under
hostname. You can also enter "*" or "all" as the value for hostname. This is then
used as the default value when no entry can be found for a specific Line Server.
Important: All Line Servers should always be listed in every configuration file. In
particular, the name of the local computer must be included (or at least an entry for
'*').
Installation Manual SIPLACE Engineering Data Manager (EDM) Version 1.9 Issue 02/2009
36
5.2.3.16 Communication timeout
Key:
communicationTimeout
Type:
Time
Default:
P0Y0M0DT0H1M0S (= 1 minute)
Valid for:
Line server
Master server
Clearing pool
Description:
Time period in which a message must be received from a particular communication
partner. The setting should generally not be changed. The other options are as
follows (from left to right):
Y = years
M = months
D = days
H = hours
M = minutes
S = seconds