00196806-01_IM_EDM_1.9_EN.pdf - 第31页

Installation Manu al SIPLACE Engine ering Data Manag er (EDM) Version 1 .9 02/2011 Edition 31 / 65 5.2.3.3 Distribution list for EDM notifications Key: notificationDistri butorClass Type: Class Default: Siemens.Si placeP…

100%1 / 65
Installation Manual SIPLACE Engineering Data Manager (EDM) Version 1.9 Issue 02/2009
30
5.2.3.1 Server type
Key:
serverType
Type:
Enum
Values:
LINE
MASTER
BOTH
CLEARINGPOOL
Valid for:
Line server
Master server
Clearing pool
Description:
Specifies the type of installation. The EDM server is started as a Line Server,
Master Server or hybrid depending on this setting (should only be used for test
purposes).
5.2.3.2 Help folder
Key:
helpDirectory
Type:
Path
Default:
[AppDir]\help
Valid for:
Line server
Master server
Clearing pool
EDM Tool
Description:
Folder for online documentation
Installation Manual SIPLACE Engineering Data Manager (EDM) Version 1.9 02/2011 Edition
31 / 65
5.2.3.3 Distribution list for EDM notifications
Key:
notificationDistributorClass
Type:
Class
Default:
Siemens.SiplacePro.EDM.DataExchange.EmailDistributor,
DataExchange
Valid for:
Master server
Description:
Class, i.e. implementation of the notification service. At the present, distribution via
email is available using the default value as a reference.
5.2.3.4 Configuration of EDM notification traffic
Key:
notificationDistributorConfiguratorClass
Type:
Class
Default:
Siemens.SiplacePro.EDM.UserInterface.EmailConfigurator,
UserInterface
Valid for:
Master server
Description:
Configuration dialog box for the notification service. The actual configuration of the
notification service depends on its implementation. Configuration of an email service
referenced using the default value is currently supported.
Installation Manual SIPLACE Engineering Data Manager (EDM) Version 1.9 Issue 02/2009
32
5.2.3.5 Notification interval
Key:
notificationInterval
Type:
Time
Default:
P0Y0M0DT0H15M0S (= 15 minutes)
Valid for:
Line server
Description:
Time period during which the change notifications will be collected on the Line
Servers before they are sent to the Master Server. The other options are as
follows (from left to right):
Y = years
M = months
D = days
H = hours
M = minutes
S = seconds
The period should not be shorter than 5 minutes.
5.2.3.6 Notification storage
Key:
notificationStorage
Type:
Endpoint
Default:
notificationStorage
Valid for:
Line server
Description:
Buffer for collected change notifications.
5.2.3.7 Master server
Key:
masterServer
Type:
String
Valid for:
Line server
Master server
Clearing pool
Description:
Network ID of the Master Server. Windows computer name only. IP addresses are
not permitted.
5.2.3.8 Transceiver
Key:
transceiverClass
Type:
Class
Default:
Siemens.SiplacePro.EDM.DataExchange.MsmqTransceiver,
DataExchange
Valid for:
Line server