Installation Manu al SIPLACE Engine ering Data Manag er (EDM) Version 1 .9 02/2011 Edition 57 / 65 5.4.1.3 Line server Figure 19 Line server s Here you spec ify the list of Line Servers for which the app lication tem pla…

100%1 / 65
Installation Manual SIPLACE Engineering Data Manager (EDM) Version 1.9 Issue 02/2009
56
Figure 17 Forced pull mode configuration
5.4.1.2 Overwriting
Figure 18 Settings for overwriting object types
You can select the object types to be overwritten when the data is imported to the line here.
Installation Manual SIPLACE Engineering Data Manager (EDM) Version 1.9 02/2011 Edition
57 / 65
5.4.1.3 Line server
Figure 19 Line servers
Here you specify the list of Line Servers for which the application template is to apply. The names in this
list must also be located in the endPointConfig (see 5.2.3.13) of the application settings.
5.4.2 Email configuration
EDM email notification uses SMTP to distribute notifications arriving at the Master Server. The following
must be configured:
• The network address of the SMTP server
• The sender to be entered in the message
• A set of distribution lists
Email distribution lists make it possible to keep email traffic to a minimum and to send the emails to
precisely the person(s) responsible. A distribution list only responds to notifications from a specific line
which contain changes to specific object types.
Installation Manual SIPLACE Engineering Data Manager (EDM) Version 1.9 Issue 02/2009
58
Figure 20 Configuration of email distribution lists
The storage location of the configuration file should be specified for informational purposes and must not
be changed. Direct manipulation of the configuration file should also be avoided.
5.4.2.1 Setting up a new list
A line must be selected before a new distribution list can be added. A name and a comment are assigned
to each new list.
5.4.2.2 Configuring a list
After a distribution list has been selected, the email addresses of the recipients and the object types or
EDM events monitored by the list can be entered. All recipients on the distribution list receive emails
regarding notifications which refer to one of the selected object types. Only those notifications are taken
into account that originate from the line for which the distribution list was created.