SOM-2079-001_w.pdf - 第106页

103 SOM-2079 1005-001 6.9 自動段取り Table 11 異常 ID 異常名、説明、要因および復帰方法 490601 Conveyor Width Automatic Adjustment The PWC axis for conveyor width adjustment cannot be driven. The L1 axis might be located lower than the pass lin…

100%1 / 179
102
SOM-2079
1005-001
異常 ID 異常名、説明、要因および復帰方法
48010f Device Inspect
Time-Out of Recognition ON Response
-----
480110 Device Inspect
Time Out of Image Capture
-----
480111 Device Inspect
Time Out of Image Capture Cancel
-----
480112 Device Inspect
Error Response of Image Capture Cancel
-----
480113 Device Inspect
Time Out of Recognition Result Response
-----
6.8 部品認識
103
SOM-2079
1005-001
6.9 自動段取り
Table 11
異常 ID 異常名、説明、要因および復帰方法
490601 Conveyor Width Automatic Adjustment
The PWC axis for conveyor width adjustment cannot be driven. The L1 axis might
be located lower than the pass line.
-----
490602 Conveyor Width Automatic Adjustment
The PWC axis for conveyor width adjustment cannot be driven. The L2 axis might
be located lower than the pass line.
-----
490603 Conveyor Width Automatic Adjustment
A PCB exists on the L conveyor.
-----
490604 Conveyor Width Automatic Adjustment
A PCB exists on the R conveyor.
-----
490605 Conveyor Width Automatic Adjustment
A PCB exists on the R conveyor.
-----
490606 Conveyor Width Automatic Adjustment
The PWC axis for conveyor width adjustment cannot be driven. The L axis might
be located lower than the pass line.
-----
490607 Conveyor Width Automatic Adjustment
An error occurred in the PWC axis while the conveyor width was being changed.
-----
490608 Conveyor Width Automatic Adjustment
An error occurred in the PWC axis while the conveyor width was being changed.
-----
490609 Conveyor Width Automatic Adjustment
The PWC axis is not zeroed completely.
-----
49060a Conveyor Width Automatic Adjustment
An error occurred in the PWC axis while the conveyor width was being changed
through an smooth inching operation.
-----
49060b Conveyor Width Automatic Adjustment
T
h
e current position of the L1 axis is not managed because the axis is not zeroed.
-----
49060c Conveyor Width Automatic Adjustment
Th
e current position of the L2 axis is not managed because the axis is not zeroed.
-----
6.9 自動段取り
104
SOM-2079
1005-001
異常 ID 異常名、説明、要因および復帰方法
49060d Conveyor Width Automatic Adjustment
The L1 axis was not zeroed successfully.
-----
49060e Conveyor Width Automatic Adjustment
The L2 axis was not zeroed successfully.
-----
49060f Conveyor Width Automatic Adjustment
The BPC axis was not zeroed successfully.
-----
490610 Conveyor Width Automatic Adjustment
The current position of the X1 axis is not managed because the axis is not
zeroed.
-----
490611 Conveyor Width Automatic Adjustment
The current position of the X2 axis is not managed because the axis is not
zeroed.
-----
490612 Conveyor Width Automatic Adjustment
The current position of the Y axis is not managed because the axis is not zeroed.
-----
490613 Conveyor Width Automatic Adjustment
The escape operation of the X axis ended in an error condition.
-----
490614 Conveyor Width Automatic Adjustment
The escape operation of the Y axis ended in an error condition.
-----
490615 Conveyor Width Automatic Adjustment
The support pins could not ascend because the maximum conveyor width was
not obtained.
-----
490616 Conveyor Width Automatic Adjustment
The current PCB width was not obtained because the pattern program data is not
defined.
-----
490617 Conveyor Width Automatic Adjustment
Software limit
-----
490618 Conveyor Width Automatic Adjustment
There is a PCB on the conveyor
-----
490619 Conveyor Width Automatic Adjustment
Failed in Program Change Operation(Data Error).
-----
6.9 自動段取り