SOM-2079-001_w.pdf - 第117页

1 14 SOM-2079 1005-001 6.10 ヘッド関係 Table 12 異常 ID 異常名、説明、要因および復帰方法 4A0101 Head Zero Return NL axis zeroing Error. Please confirm the nozzle has not fallen when you push the beam by the hand. When the lock of a safety door …

100%1 / 179
113
SOM-2079
1005-001
異常 ID 異常名、説明、要因および復帰方法
496768 Standard Position Adjustment Error
An overrun sensor (-) was detected during output conveyor operation.
Perform the zeroing operation for the output conveyor.
496801 Transfer Communication Error
An error occurred in the transfer driver comunications.
1. Check the communications cable.\r\n2. Check the power cable.\r\n3. Check
transfer motor driver's address setting.\r\n4. Check the fuse[F1,F2,F3] on [U85] in
CPU2. If the fuse is blown, replace [U85] board.
496802
-----
496803
-----
496804
-----
6.9 自動段取り
114
SOM-2079
1005-001
6.10 ヘッド関係
Table 12
異常 ID 異常名、説明、要因および復帰方法
4A0101 Head Zero Return
NL axis zeroing Error. Please confirm the nozzle has not fallen when you push
the beam by the hand.
When the lock of a safety door cannot be canceled, please push an emergency
stop button. (Please confirm the nozzle has not fallen when you push the beam
by the hand.) Please check error on a "MAINT-DVC CHK- MOTOR" screen.
4A0102 Head Zero Return
HL axis zeroing Error. Please confirm the nozzle has not fallen when you push
the beam by the hand.
When the lock of a safety door cannot be canceled, please push an emergency
stop button. (Please confirm the nozzle has not fallen when you push the beam
by the hand.) Please check error on a "MAINT-DVC CHK- MOTOR" screen.
4A0103 Head Zero Return
L1 axis zeroing Error. Please confirm the nozzle has not fallen when you push the
beam by the hand.
When the lock of a safety door cannot be canceled, please push an emergency
stop button. (Please confirm the nozzle has not fallen when you push the beam
by the hand.) Please check error on a "MAINT-DVC CHK- MOTOR" screen.
4A0104 Head Zero Return
L2 axis zeroing Error. Please confirm the nozzle has not fallen when you push the
beam by the hand.
When the lock of a safety door cannot be canceled, please push an emergency
stop button. (Please confirm the nozzle has not fallen when you push the beam
by the hand.) Please check error on a "MAINT-DVC CHK- MOTOR" screen.
4A0105 Head Zero Return
L3 axis zeroing Error. Please confirm the nozzle has not fallen when you push the
beam by the hand.
When the lock of a safety door cannot be canceled, please push an emergency
stop button. (Please confirm the nozzle has not fallen when you push the beam
by the hand.) Please check error on a "MAINT-DVC CHK- MOTOR" screen.
4A0201 NL Axis Warming Up
An error was found at the motor (rear).
-----
4A0202 NL Axis Warming Up
An error was found at the motor (front).
-----
4A0203 NL Axis Warming Up
A parameter error was found at the motor (rear).
-----
4A0204 NL Axis Warming Up
A parameter error was found at the motor (front).
-----
6.10 ヘッド関係
115
SOM-2079
1005-001
異常 ID 異常名、説明、要因および復帰方法
4A0205 NL Axis Warming Up
An error was found during motor (rear) startup.
-----
4A0206 NL Axis Warming Up
An error was found during motor (front) startup.
-----
4A0207 NL Axis Warming Up
An error for timeout was found at the motor (rear).
-----
4A0208 NL Axis Warming Up
An error for timeout was found at the motor (front).
-----
4A0209 NL Axis Warming Up
The operation was not performed due to limitation of the NS/DD motor (rear)
position.
-----
4A020A NL Axis Warming Up
The operation was not performed due to limitation of the NS/DD motor (front)
position.
-----
4A020B NL Axis Warming Up
The operation was not performed due to Leady Flag (rear) OFF.
-----
4A020C NL Axis Warming Up
The operation was not performed due to Leady Flag (front) OFF.
-----
4A0301 Beam Escape Operation
The motor error occurred in the beam escape operation.
-----
4A0302 Beam Escape Operation
The descent of the NL axis was detected in the beam escape operation.
Please check whether the nozzle is descending.
4A0401 Nozzle Abnormality Watch
Odd type nozzle on the head was not detected.
There is a nozzle drop. Check the head and head moving area. Als o check
PCB for missing placements. A possible cause of nozzle drop is pushing
component too hard to pickup and place. Check data.
4A0402 Nozzle Abnormality Watch
When the nozzle descended, the present location disagreement of the rotation
axis was detected.
There is a possibility that the nozzle has fallen, and confi
rm it in the head and the
machine, please.
6.10 ヘッド関係