27 SOM-2079 1005-001 異常 ID 異常名、説明、要因および復帰方法 423307 Input Cnvr Error The PCB was transported a predetermined distance, but the operation was not completed. There is a possibility that the P.C.B fell over from conveyer whe…

26
SOM-2079
1005-001
異常 ID 異常名、説明、要因および復帰方法
422325 Cnvr Positioning1 Error
Error data was transferred in the process of the bad mark transfer.
Remove the P.C.B. and delete the Bad Mark information after checking the
number of the unit P.C.B.'s in the pattern program.
423101 Input Cnvr PCB Overtime
The PCB transport (carry in) from Cnvr Positioning1 did not end in prescribed
time.
Por favor, verifi
que posicionamento da PCB no conveyor e continue a operação
423102 Input Cnvr PCB Overtime
The PCB transport (exhaust) to Cnvr Positioning1 did not end in prescribed time.
Por favor, verifique posicionamento da PCB no conveyor e continue a operação
423103 Input Cnvr PCB Overtime
The reversal positioning operation did not end in prescribed time.
Por favor, verifique posicionamento da PCB no conveyor e continue a operação
423201 Input Cnvr PCB Detection
There are 2 PCB's around the inlet and the outlet on the conveyor.
Por favor, verifique posicionamento da PCB no conveyor e continue a operação
423202 Input Cnvr PCB Detection
There is no PCB on the conveyer. After the PCB carrying in ended, it can not able
to be detected.
Por favor, verifique posicionamento da PCB no conveyor e continue a operação
423203 Input Cnvr PCB Detection
The conveyer entrance sensor detected PCB
Por favor, verifique posicionamento da PCB no conveyor e continue a operação
423204 Input Cnvr PCB Detection
The PCB was detected with the conveyer entrance sensor.
Please remove the P.C.B on a conveyor. Production can be continued.
423301 Input Cnvr Error
The carrying in operation was not able to begin.
-----
423302 Input Cnvr Error
The error was detected while carrying in was operating.
Por favor, verifique posicionamento da PCB no conveyor e continue a operação
423303 Input Cnvr Error
The exhaust operation was not able to begin.
-----
423304 Input Cnvr Error
The error was detected while exhaust was operating.
Por favor, verifique posicionamento da PCB no conveyor e continue a operação
423305 Input Cnvr Error
The reversal positioning operation was not able to begin.
-----
423306 Input Cnvr Error
The error was detected while the reversal positioning was operating.
Por favor, verifique posicionamento da PCB no conveyor e continue a operação
6.3 コンベア

27
SOM-2079
1005-001
異常 ID 異常名、説明、要因および復帰方法
423307 Input Cnvr Error
The PCB was transported a predetermined distance, but the operation was not
completed.
There is a possibility that the P.C.B fell over from conveyer whether a board is
caught. Please confi
rm it over a conveyer.
423308 Input Cnvr Error
The process of inside signal between conveyors failed.
Por favor, verifique posicionamento da PCB no conveyor e continue a operação
423309 Input Cnvr Error
Speed reduction was not performed during PCB transfer operation.
Please return the P.C.B. to the proper position when it is sitting between the
conveyors otherwise, remove the P.C.B. And, the P.C.B. detection sensor might
have had a wrong detection, so please check it to make detections correctly.
424101 Cnvr Positoining2 Overtime
The PCB transport (carry in) from input cnvr did not end in prescribed time.
Por favor, verifique posicionamento da PCB no conveyor e continue a operação
424102 Cnvr Positoining2 Overtime
The PCB transport (exhaust) to output cnvr did not end in prescribed time.
Por favor, verifique posicionamento da PCB no conveyor e continue a operação
424103 Cnvr Positoining2 Overtime
The rising operation of the backup base did not end in prescribed time.
-----
424104 Cnvr Positoining2 Overtime
The descent operation of the backup base did not end in prescribed time.
-----
424106 Cnvr Positoining2 Overtime
The positioning change operation did not end in prescribed time.
Por favor, verifique posicionamento da PCB no conveyor e continue a operação
424107 Input Cnvr Error
The reversal positioning operation did not end in prescribed time.
Por favor, verifique posicionamento da PCB no conveyor e continue a operação
424108 Input Cnvr Error
The PCB transfer operation could not be completed in time.
Por favor, verifique posicionamento da PCB no conveyor e continue a operação
424109 Input Cnvr Error
The process of the Bad Mark transfer was not completed within regular hours.
Por favor, verifique posicionamento da PCB no conveyor e continue a operação
424201 Cnvr Positioning2 PCB Detection
PCB's were at inlet and outlet of cnvr.
Por favor, verifique posicionamento da PCB no conveyor e continue a operação
424202 Cnvr Positioning2 PCB Detection
There is no PCB on the conveyer. After the PCB carrying in ended, it can not able
to be detected.
Por favor, verifique posicionamento da PCB no conveyor e continue a operação
6.3 コンベア

28
SOM-2079
1005-001
異常 ID 異常名、説明、要因および復帰方法
424203 Cnvr Positioning2 PCB Detection
No PCB on the cnvr After positioning released, PCB could not be detected.
Por favor, verifique posicionamento da PCB no conveyor e continue a operação
424204 Cnvr Positioning2 PCB Detection
The conveyer entrance sensor detected PCB
Por favor, verifique posicionamento da PCB no conveyor e continue a operação
424205 Cnvr Positioning2 PCB Detection
The PCB that has not been positioned exists.
Please position the P.C.B.
424206 Cnvr Positioning2 PCB Detection
An unsuitable detected state of the sensor is being kept.
Please remove the factor that the sensor detects. (The operation delay of the dirt
of the sensor or Z clamping descent is thought. )
424207 Cnvr Positioning2 PCB Detection
The PCB was unsuitable detected at the time of a carrying-in operation start.
Please check whether the sensor of a conveyor is operating normally and check
whether a P.C.B can convey normally by manual conveyance.
424208 Cnvr Positioning2 PCB Detection
The PCB was detected with the conveyer entrance sensor.
Please return the P.C.B. to the proper position when it is sitting between the
conveyors otherwise, remove the P.C.B. And, the P.C.B. detection sensor might
have had a wrong detection, so please check it to make detections correctly.
424301 Cnvr Positioning2 Error
The carrying in operation was not able to begin.
-----
424302 Cnvr Positioning2 Error
The error was detected while carrying in was operating.
Por favor, verifi
que posicionamento da PCB no conveyor e continue a operação
424303 Cnvr Positioning2 Error
The exhaust operation was not able to begin.
-----
424304 Cnvr Positioning2 Error
The error was detected while exhaust was operating.
Por favor, verifique posicionamento da PCB no conveyor e continue a operação
424305 Cnvr Positioning2 Error
The error was detected while the backup base was rising.
-----
424306 Cnvr Positioning2 Error
The error was detected while the backup base was descending.
-----
424307 Cnvr Positioning2 Error
Rise operation of a PCB stopper is not completed.
Please check a stopper.