SOM-2079-001_w.pdf - 第144页

141 SOM-2079 異常 ID 異常名、説明、要因および復帰方法 601a04 Linear measure correction re-teach The linear measure control has an error. ----- 601a05 Linear measure correction re-teach The correction value could not be created. Re-teach i…

100%1 / 179
140
SOM-2079
異常 ID 異常名、説明、要因および復帰方法
601703 V.Bend Detection teach
Error received data.
Please confirm connected cable of lead fi
lting unit PC and the main body.
(network cable)
601704 V.Bend Detection teach
Recog Process error
Please confirm the treatment device in the depository for the lead fi
lting.
601705 V.Bend Detection teach
JIG Pick-up Error
Please return the treatment device for lead filting to the depository.
601706 V.Bend Detection teach
The nozzle is not installed in nozzle 1.
Please select nozzle 1, pick up the JIG, and execute recognition.
601801 Tray Teach
Recog Mark error
Manual Alignment
601802 Tray Teach
Recog Process error
-----
601803 Tray Teach
Tray starting point position offset is inaccurate (X or Y of an instruction result is a
minus value).
Please perform pick-up position teaching after performing traverse axis draw
teaching.
601804 Tray Teach
Recog Mark error
Manual Alignment
601805 Tray Teach
Recog Process error
-----
601901 Bad Mark Sensor Set
Errors occurred during Bad mark sensor setting.
Please push a [CANCEL] button and perform sensor setting again.
601a01 Linear measure correction re-teach
The linear measure reading is abnormal.
Please confi
rm whether the nozzle has adhered to the position.
601a02 Linear measure correction re-teach
Offset correction can not be completed. Please use the big nozzle(HA05) teach
again and adjust the light & receive optical Axis
-----
601a03 Linear measure correction re-teach
Nozzle can not be detected.
-----
1005-001
6.14 自動教示
141
SOM-2079
異常 ID 異常名、説明、要因および復帰方法
601a04 Linear measure correction re-teach
The linear measure control has an error.
-----
601a05 Linear measure correction re-teach
The correction value could not be created. Re-teach it with a thick nozzle (HA05),
otherwise adjust the emitting and receiving optical-axis. (Correction Error: Sample
All E/R)
-----
601a06 Linear measure correction re-teach
The correction value could not be created. Re-teach it with a thick nozzle (HA05),
otherwise adjust the emitting and receiving optical-axis. (Correction Error: Sample
All E/NR)
-----
601a07 Linear measure correction re-teach
The correction value could not be created. Re-teach it with a thick nozzle (HA05),
otherwise adjust the emitting and receiving optical-axis. (Correction Error: Sample
All E/R & E/NR detection error)
-----
601a08 Linear measure correction re-teach
The correction value could not be created. Re-teach it with a thick nozzle (HA05),
otherwise adjust the emitting and receiving optical-axis. (Correction Error:
Shortage of Samples)
-----
601a09 Linear measure correction re-teach
The correction value could not be created. Re-teach it with a thick nozzle (HA05),
otherwise adjust the emitting and receiving optical-axis. (Correction Error: Failed
in the generation of the correction formula.)
-----
601a0a Linear measure correction re-teach
The correction value could not be created. Re-teach it with a thick nozzle (HA05),
otherwise adjust the emitting and receiving optical-axis. (Correction Error: Inside
accuracy check error)
-----
601a0b Linear measure correction re-teach
The measurement value of the nozzle is not within 0.2mm - 0.6mm.
Adjust the height of the linear measure sensor otherwise, replace it.
601a0c Linear measure correction re-teach
The firmware is not applicable to the correcting creation.
Update the version by Ver.008 fi
rmware or later.
601b01 Automatic teaching
The nozzle is not installed.
Please install the nozzle.
601c01 Camera bad mark teaching
There is spots in the bad mark inspection area.
-----
1005-001
6.14 自動教示
142
SOM-2079
異常 ID 異常名、説明、要因および復帰方法
601d01 Library teaching
Abnormality was found in the division recognition position movement when the
library was taught.
Please make a new library instruction again.
601e01 Board height measurement teach
Recognition mark is abnormal
Please carry out remaining teach after having manual alignment.
601e02 Board height measurement teach
Abnormality occurred during board height measurement teach movement.
-----
601e03 Board height measurement teach
Failed teaching: The measurement is wrong.
Clean the surface of the jig.
601e04 Board height measurement teach
Failed Teaching: The jig is tilting.
Reposition it with the P.C.B. thickness reviewed.
601e05 Board height measurement teach
Failed Teaching: Jig Recognition Error
Check the condition in locating the jig P.C.B.
601f01 NL Axis offset teach
Linear measure was found abnormality while measuring.
-----
601f02 NL Axis offset teach
The result of the linear measure sensor is out of the tolerance.
-----
601f03 NL Axis offset teach
An error for the NS axis movement occurred.
-----
601f04 NL Axis offset teach
Time out of the NS axis movement occurred.
-----
601f05 NL Axis offset teach
An error for the DD axis movement occurred.
-----
601f06 NL Axis offset teach
Time out of the DD axis movement occurred.
-----
601f07 NL Axis offset teach
An error for the NL axis movement occurred.
-----
601f08 NL Axis offset teach
Time out of the NL axis movement occurred.
-----
1005-001