SOM-2079-001_w.pdf - 第177页

174 SOM-2079 装置情報コード 表示区分 A( 装置情報の概要 ) 表示区分 B( 装置情報の詳細 ) 809a01 Tray Resupply Release the lock of the safety cover in the tray resupply section and change the tray. After change, lock the cover and press the Resupply but…

100%1 / 179
173
SOM-2079
装置情報コード 表示区分 A( 装置情報の概要 )
表示区分 B( 装置情報の詳細 )
809706 PCB Stopper
"Disable"was set for the reversal PCB stopper in the system data/ pattern
program data.
809711 PCB Stopper
The rise operating time of the P.C.B. stopper is too fast. Please adjust it so that
an operating time becomes 90-190ms.
809712 PCB Stopper
The rise operating time of the reversal P.C.B. stopper is too fast. Please adjust it
so that an operating time becomes 90-190ms.
809713 PCB Stopper
The rise operating time of the P.C.B. stopper is too slow. Please adjust it so that
an operating time becomes 90-190ms.
809714 PCB Stopper
The rise operating time of the reversal P.C.B. stopper is too slow. Please adjust it
so that an operating time becomes 90-190ms.
809715 PCB Stopper
The drop operating time of the P.C.B. stopper is too fast. Please adjust it so that
an operating time becomes 190-290ms.
809716 PCB Stopper
The drop operating time of the reversal P.C.B. stopper is too fast. Please adjust it
so that an operating time becomes 190-290ms.
809717 PCB Stopper
The drop operating time of the P.C.B. stopper is too slow. Please adjust it so that
an operating time becomes 190-290ms.
809718 PCB Stopper
The drop operating time of the reversal P.C.B. stopper is too slow. Please adjust
it so that an operating time becomes 190-290ms.
809801 Feeder alternate condition is disable.
Original and alternated feeders have had pick-up errors and they are under
disabled status. After fi
nding the cause of pick-up errors, go to the main menu,
then [OPERATION], [Altn Mode], select feeder lane number, enable feeder(s)
to clear disabled status, go back to the main menu and press the start button to
resume.
809901 Flux residual quantity detection sensor
It reached the predetermined number of times of a dip, but automatic reload
movement was not carried out. Please confirms quantity of a flux on a disk, and
confirm sensitivity of a sensor.
809902 Flux residual quantity detection sensor
Automatic reload movement was surplus carried out for the predetermined
number of times of a dip. Please confirms quantity of a flux on a disk, and confi
rm
sensitivity of a sensor.
1005-001
6.19 装置情報
174
SOM-2079
装置情報コード 表示区分 A( 装置情報の概要 )
表示区分 B( 装置情報の詳細 )
809a01 Tray Resupply
Release the lock of the safety cover in the tray resupply section and change the
tray.
After change, lock the cover and press the Resupply button.
809b01 P.C.B. height measure
The measurement had an error but it has been recovered by measuring the
multiple points.
809b02 P.C.B. height measure
Abnormal measured value was found but it has been recovered by measuring the
multiple points.
809C01 Library Bulk Feeder Check
The bulk feeder of library is not in agreement. Please check the library and bulk
feeder.
809d01 Cutter auto return
The cutter auto return mode was performed.
809e01 Shuttle Tray Pickup Loc
The P&P X axis position is limit over(+). Please check the comp position.
809e02 Shuttle Tray Pickup Loc
The P&P X axis position is limit over(-). Please check the comp position.
809e03 Shuttle Tray Pickup Loc
The traverse axis position is limit over(+). Please check the comp position.
809e04 Shuttle Tray Pickup Loc
The traverse axis position is limit over(-). Please check the comp position.
809e05 Shuttle Tray Pickup Loc
The shuttle axis position is limit over(+). Please check the comp position.
809e06 Shuttle Tray Pickup Loc
The shuttle axis position is limit over(-). Please check the comp position.
1005-001
6.19 装置情報
175
SOM-2079
6.20 システム異常
Table 22
異常 ID 異常名、説明、要因および復帰方法
FE0101 Auto Control Error
In auto control the operation can't be continued Error(Refer to syslog)
-----
1005-001
6.20 システム異常