SOM-2079-001_w.pdf - 第135页
132 SOM-2079 異常 ID 異常名、説明、要因および復帰方法 500c01 Comp. Vertical(Sensor) Please confirm component thickness data (T,t) of the component library. 500d01 Comp. Missing (Sensor) After Chuck ----- 500e01 Comp. Missing (Sensor) Befor…

131
SOM-2079
6.12 吸着異常
Table 14
異常 ID 異常名、説明、要因および復帰方法
500101 Comp. Missing (Sensor)
There is a possibility that the picked comps. have fallen on the feeder and please
confirm it.
500102 Comp. Missing (Sensor)
There is a possibility that the picked comps. have fallen on the feeder and please
confirm it.
500201 Vacuum Sensor Error
-----
500301 Comp. Missing (Recog)
There is a possibility that the picked comps. have fallen on the feeder and please
confirm it.
500302 Comp. Missing (Recog)
There is a possibility that the picked comps. have fallen on the feeder and please
confirm it.
500401 Comp. Recog Error
-----
500501 Shortage of Component
Shortage of Component
500502 Feeder Reload Stop
Feeder Reload Stop (Splicing)
-----
500601 V.Bend Detection Error
-----
500701 Shortage of Component (Alternated Feeder)
-----
500a01 Auto Recovery Pause
Attach the new comp. And press [READY]. Then, press [START] button to re-
start.
-----
500a02 Auto Recovery Pause
Quick recovery stop
-----
1005-001
6.12 吸着異常

132
SOM-2079
異常 ID 異常名、説明、要因および復帰方法
500c01 Comp. Vertical(Sensor)
Please confirm component thickness data (T,t) of the component library.
500d01 Comp. Missing (Sensor) After Chuck
-----
500e01 Comp. Missing (Sensor) Befor Mount
-----
500f01 Comp. Thickness(Sensor)
Please confirm component thickness data (T,t) of the component library.
501001 Comp. Missing (Sensor)
A pick-up error occurred in the pick-up operation.
After stage Ready Off, open the cover and remove the component on the feeder,
otherwise the component may hit to the head.
501101 Shortage of lot component
Shortage of lot component
Shortage of component occurred with a lot unit. Reload the component.
501201 Shortage of lot component
Please select "continue" or "Cancel".
-----
501301 Linear measure self check
Linear measure self check error occurred.
Check the linear measure function.
501401 Comp. Missing (Sensor and Camera)
There is a possibility that the picked comps. have fallen on the feeder and please
confirm it.
1005-001
6.12 吸着異常

133
SOM-2079
6.13 生産運転異常
Table 15
異常 ID 異常名、説明、要因および復帰方法
510101 Auto Run Error
API Error
Please push the [emergency stop] button and execute Warm Start.
510102 Auto Run Error
Other axis positioning timeout
Please push the [emergency stop] button and execute Warm Start.
510103 Auto Run Error
Motor start preprocess error
Please push the [emergency stop] button and execute Warm Start.
510104 Auto Run Error
Motor start preprocess check timeout
Please push the [emergency stop] button and execute Warm Start.
510105 Auto Run Error
Motor positioning error
Please push the [emergency stop] button and execute Warm Start.
510106 Auto Run Error
Motor positioning timeout
Please push the [emergency stop] button and execute Warm Start.
510107 Auto Run Error
Motor mode set error
Please push the [emergency stop] button and execute Warm Start.
510108 Auto Run Error
Motor mode set timeout
Please push the [emergency stop] button and execute Warm Start.
510109 Auto Run Error
Motor positioning data set error
Please push the [emergency stop] button and execute Warm Start.
51010a Auto Run Error
Motor positioning data set timeout
Please push the [emergency stop] button and execute Warm Start.
51010b Auto Run Error
Motor start condition error
Please push the [emergency stop] button and execute Warm Start.
51010c Auto Run Error
Motor start command error
Please push the [emergency stop] button and execute Warm Start.
51010d Auto Run Error
Motor start command timeout
Please push the [emergency stop] button and execute Warm Start.
51010e Auto Run Error
Motor function set error
Please push the [emergency stop] button and execute Warm Start.
1005-001
6.13 生産運転異常