異常 ID 異常名、説明、要因および復帰方法
49061a Conveyor Width Automatic Adjustment
Failed in Program Change Operation(Time out).
-----
49061b Conveyor Width Automatic Adjustment
Backup Base zeroing Error.
-----
49061c Conveyor Width Automatic Adjustment
Head Up/Down Axis Zeroing Error.
-----
49061d Conveyor Width Automatic Adjustment
The PCB was detected on the Input conveyor.
Please remove the P.C.B on a Input conveyor.
49061e Conveyor Width Automatic Adjustment
The PCB was detected on the Cnvr Positioning1.
Please remove the P.C.B on a Cnvr. Positioning1.
49061f Conveyor Width Automatic Adjustment
The PCB was detected on the central conveyor.
Please remove the P.C.B on a center conveyor.
490620 Conveyor Width Automatic Adjustment
The PCB was detected on the Cnvr Positioning2.
Please remove the P.C.B on a Cnvr. Positioning2.
490621 Conveyor Width Automatic Adjustment
The PCB was detected on the Output conveyor.
Please remove the P.C.B on a Output conveyor.
490622 Conveyor Width Automatic Adjustment
The width of arrangements of the conveyer is set smaller than 56mm.
Please adjust the setting (width + clearance) to 56mm or more.
490690 Conveyor Width Automatic Adjustment
Auto Set-up Error(Others).
-----
490701 Nozzle set-up
Nozzle Stocker is not set.
Please check whether it is correctly set to the stocker base.
490702 Nozzle set-up
Motor Error Detection.
-----
490703 Nozzle set-up
Nozzle Stocker Shutter open/close failed.
There is no fl
oat going up of a nozzle, or please check whether there is any
connection etc. in opening and closing.
490704 Nozzle set-up
Nozzle Stocker up/dowon failed.
There is no float going up of a nozzle, or please check whether there is any
connection etc. in opening and closing.
6.9 自動段取り

106
SOM-2079
1005-001
異常 ID 異常名、説明、要因および復帰方法
490705 Nozzle set-up
Nozzle(s) was not found in the stocker.
Check whether there is any difference in stocker arrangement data and real
arrangement.
490706 Nozzle set-up
Head nozzle existence confi
rmation has error.
Please check whether there is any difference in head arrangement data and real
arrangement.
490707 Nozzle set-up
There is no free space for nozzle storing. Please confirm the arrangement data.
Please confi
rm the Stocker arrangement data.
490708 Nozzle set-up
There are neither a free space nor a nozzle for nozzle exchange.
Please set up an insufficient nozzle in Noz stocker.
490709 Nozzle set-up
Nozzle exchange abnormal data was found.
Please confirm the nozzle arrangement and the Stocker arrangement data.
49070a Nozzle set-up
Nozzle stocker position teaching failed.
Please teach the Noz stocker position again on the instruction screen.
49070b Nozzle set-up
Placement Hd / Noz data is not corresponding to the real arrangement.
Please confirm the real arrangement of the head nozzle arrangement data and
the head.
49070c Nozzle set-up
Nozzle level teach error Detection.
Please execute the nozzle level teaching again on the nozzle level teach screen,
and confirm there is no unexpected value.
49070d Nozzle set-up
It failed in the nozzle placement check. Confirm the recognition image and select
the nozzle existence.
Please select a recognition image and choose the existence of a nozzle.
49070e Nozzle set-up
The remains nozzle was detected on the head. The nozzle cannot be set to this
position.
Please confirm the nozzle has not adhered to the position. Moreover, please
clean the linear measure when not adhering.
49070f Nozzle set-up
Abnormal nozzle level detected. Possibilities are the nozzle was not fully inserted
in the head, or linear measure saw dust or scratch.
Please confirm whether the nozzle has adhered to the position.
490710 Nozzle set-up
The receipt nozzle was undetectable on the head.
Please confirm whether the nozzle has adhered to the position.
6.9 自動段取り

107
SOM-2079
1005-001
異常 ID 異常名、説明、要因および復帰方法
490711 Nozzle set-up
The remains nozzle was detected on the head.
Please confirm the nozzle has not adhered to the position. Moreover, please
clean the linear measure when not adhering.
490712 Nozzle set-up
The linear measure error occurred in the head nozzle existence check.
Please confirm the nozzle arrangement, and execute the level teaching.
490713 Nozzle set-up
The nozzle exchange sequence error occurred.
Please confirm the nozzle placement.
490714 Nozzle set-up
The nozzle placement in Nozzle stocker is different from the nozzle data.
Please confirm the nozzle placement.
490715 Nozzle set-up
It failed in nozzle ID detection.
Please confirm the nozzle ID.
490716 Nozzle set-up
Time-out of close nozzle stocker operation.
Nozzle stocker was opened for safety. Please confirm whether there is no rise to
the surface the nozzle is not in opening and shutting caught state.
490717 Nozzle set-up
A PCB was detected on the input conveyor.
Remove the P.C.B. from the input conveyor.
490718 Nozzle set-up
A PCB was detected on the positioning 1 conveyor.
Remove the P.C.B. from the positioning 1conveyor.
490719 Nozzle set-up
A PCB was detected on the central conveyor.
Remove the P.C.B. from the center conveyor.
490720 Nozzle set-up
A PCB was detected on the positioning 2 conveyor.
Remove the P.C.B. from the positioning 2 conveyor.
490721 Nozzle set-up
A PCB was detected on the output conveyor.
Remove the P.C.B. from the output conveyor.
490722 Nozzle set-up
A
n
error occurred with the nozzle existence check in the stocker before the nozzle
is stored.
-----
490723 Nozzle set-up
It failed in the nozzle storage check. Confirm the recognition image and select the
nozzle existence.
-----
6.9 自動段取り