139 SOM-2079 異常 ID 異常名、説明、要因および復帰方法 600803 Feeder offset(A) teach Feeder connection is set in test mode. ----- 600804 Feeder offset(A) teach The data of the feeder was not able to be read. ----- 600805 Feeder offset(A) t…

138
SOM-2079
異常 ID 異常名、説明、要因および復帰方法
600303 Head Rotate Theta Axis offset
-----
600401 Head Rotate center offset teach
-----
600402 Head Rotate center offset teach
-----
600501 Reference mark position teach
-----
600502 Reference mark position teach
-----
600503 Reference mark position teach
-----
600504 Reference mark position teach
-----
600601 Nozzle position offset teach
-----
600602 Nozzle position offset teach
-----
600701 Fly recog Offset teach
-----
600702 Fly recog Offset teach
-----
600703 Fly recog Offset teach
-----
600704 Fly recog Offset teach
-----
600801 Feeder offset(A) teach
Please push the Feeder Ready SW
-----
600802 Feeder offset(A) teach
Feeder recog Mark Error
Manual Alignment
1005-001
6.14 自動教示

139
SOM-2079
異常 ID 異常名、説明、要因および復帰方法
600803 Feeder offset(A) teach
Feeder connection is set in test mode.
-----
600804 Feeder offset(A) teach
The data of the feeder was not able to be read.
-----
600805 Feeder offset(A) teach
Feeder recog Process time over
-----
600901 Feeder offset(B) teach
-----
601000 Master nozzle level offset teach
-----
601101 Nozzle level offset teach
The nozzle level instruction result exceeded the tolerance.
-----
601200 Y Axis offset teach
-----
601301 Nozzle stocker offset teaching
Stocker Mark #1 Recognition Error
Please select "Mnl Align Mark1" and adjust the manual.
601302 Nozzle stocker offset teaching
Stocker Mark #2 Recognition Error
Please select "Mnl Align Mark2" and adjust the manual.
601400 Msater nozzle level offset teach
-----
601501 Recog camera light teach
Recog Process error
-----
601601 Comp. Recog Camera magnifi
cation teach.
Recog Process error
-----
601701 V.Bend Detection teach
Communication time-out.
Please confirm connected cable of lead fi
lting unit PC and the main body.
(network cable)
601702 V.Bend Detection teach
Error command.
Please confirm connected cable of lead fi
lting unit PC and the main body.
(network cable)
1005-001
6.14 自動教示

140
SOM-2079
異常 ID 異常名、説明、要因および復帰方法
601703 V.Bend Detection teach
Error received data.
Please confirm connected cable of lead fi
lting unit PC and the main body.
(network cable)
601704 V.Bend Detection teach
Recog Process error
Please confirm the treatment device in the depository for the lead fi
lting.
601705 V.Bend Detection teach
JIG Pick-up Error
Please return the treatment device for lead filting to the depository.
601706 V.Bend Detection teach
The nozzle is not installed in nozzle 1.
Please select nozzle 1, pick up the JIG, and execute recognition.
601801 Tray Teach
Recog Mark error
Manual Alignment
601802 Tray Teach
Recog Process error
-----
601803 Tray Teach
Tray starting point position offset is inaccurate (X or Y of an instruction result is a
minus value).
Please perform pick-up position teaching after performing traverse axis draw
teaching.
601804 Tray Teach
Recog Mark error
Manual Alignment
601805 Tray Teach
Recog Process error
-----
601901 Bad Mark Sensor Set
Errors occurred during Bad mark sensor setting.
Please push a [CANCEL] button and perform sensor setting again.
601a01 Linear measure correction re-teach
The linear measure reading is abnormal.
Please confi
rm whether the nozzle has adhered to the position.
601a02 Linear measure correction re-teach
Offset correction can not be completed. Please use the big nozzle(HA05) teach
again and adjust the light & receive optical Axis
-----
601a03 Linear measure correction re-teach
Nozzle can not be detected.
-----
1005-001