34 SOM-2079 1005-001 異常 ID 異常名、説明、要因および復帰方法 425315 Output Cnvr Error The PCB was transported a predetermined distance, but the operation was not completed. There is a possibility that the P.C.B fell over from conveyer wh…

33
SOM-2079
1005-001
異常 ID 異常名、説明、要因および復帰方法
425303 Output Cnvr Error
The exhaust operation was not able to begin.
-----
425304 Output Cnvr Error
The error was detected while exhaust was operating.
Por favor, verifi
que posicionamento da PCB no conveyor e continue a operação
425305 Output Cnvr Error
The PCB transport to receiving position was not able to begin.
-----
425306 Output Cnvr Error
The error was detected while transpoting to the receiving position.
-----
425307 Output Cnvr Error
The operation moving to the arrangement position was not able to begin.
-----
425308 Output Cnvr Error
The error was detected while transporting to the arrangement position.
-----
425309 Output Cnvr Error
The reversal positioning operation was not able to begin.
-----
425310 Output Cnvr Error
The error was detected while the reversal positioning was operating.
Por favor, verifi
que posicionamento da PCB no conveyor e continue a operação
425311 Output Cnvr Error
Conveyor width The conveyor upper cover by output side opened during axial
operation.
Please close a cover and perform again.
425312 Output Cnvr Error
The conveyor upper cover by output side opened during production operation and
equipment operation.
Please close a cover and perform again.
425313 Output Cnvr Error
The Output conveyor upper cover opened during production operation and
equipment operation.
Please close a cover and perform again.
425314 Output Cnvr Error
It changed into the conveyor operation forbidden state during axial operation of
conveyor width. (The conveyor operation forbidden signal from output conveyor
was detected.)
Please cancel the forbidden operation state of a conveyor and perform again.
6.3 コンベア

34
SOM-2079
1005-001
異常 ID 異常名、説明、要因および復帰方法
425315 Output Cnvr Error
The PCB was transported a predetermined distance, but the operation was not
completed.
There is a possibility that the P.C.B fell over from conveyer whether a board is
caught. Please confi
rm it over a conveyer. Moreover, please execute the zeroing
o
peration of a pertinent conveyer from the screen of maintenance/unit adjustment/
conveyer when the width of the conveyer has changed.
425316 Output Cnvr Error
Abnormality occurred at the time of disposal of Board END signals.
Please start production again.
425317 Output Cnvr Error
The process of inside signal between conveyors failed.
Por favor, verifique posicionamento da PCB no conveyor e continue a operação
425318 Output Cnvr Error
Speed reduction was not performed during transferring operation.
Please return the P.C.B. to the proper position when it is sitting between the
conveyors otherwise, remove the P.C.B. And, the P.C.B. detection sensor might
have had a wrong detection, so please check it to make detections correctly.
426101 Input Conveyor Error
The initialization is imperfect.
-----
426102 Input Conveyor Error
An error occurred during zeroing operation.
Try to operate the zero return again.
426103 Input Conveyor Error
An alarm for interference is occurring.
-----
426104 Input Conveyor Error
DI was detected.
-----
426105 Input Conveyor Error
The input conveyor upper cover opened during product operation or the machine
running.
-----
426106 Input Conveyor Error
Brownout on the power source was detected.
Confirm the transfer driver.
426107 Input Conveyor Error
OT(+) was detected during product operation or the machine running.
Operate the zero return for the conveyor.
426108 Input Conveyor Error
OT(-) was detected during product operation or the machine running.
Operate the zero return for the conveyor.
6.3 コンベア

35
SOM-2079
1005-001
異常 ID 異常名、説明、要因および復帰方法
426201 Output Conveyor Error
The initialization is imperfect.
-----
426202 Output Conveyor Error
An error occurred during zeroing operation.
Try to operate the zero return again.
426203 Output Conveyor Error
An alarm for interference is occurring.
-----
426204 Output Conveyor Error
DI was detected.
-----
426205 Output Conveyor Error
T
h
e output conveyor upper cover opened during product operation or the machine
running.
-----
426206 Output Conveyor Error
Brownout on the power source was detected.
Confirm the transfer driver.
426207 Output Conveyor Error
OT(+) was detected during product operation or the machine running.
Operate the zero return for the conveyor.
426208 Output Conveyor Error
OT(-) was detected during product operation or the machine running.
Operate the zero return for the conveyor.
426301 Trapped PCB Detection
There is a PCB between conveyors of the Input and the Positioning.
Remove the P.C.B. on the conveyor.
426302 Trapped PCB Detection
There is a PCB between conveyors of the Positioning and the Output.
Remove the P.C.B. on the conveyor.
426303 Trapped PCB Detection
T
h
ere is a PCB between conveyors of the input machine and the supply conveyor.
Remove the P.C.B. on the conveyor.
426304 Trapped PCB Detection
There is a PCB between conveyors of the output and the output machine.
Remove the P.C.B. on the conveyor.
6.3 コンベア