SOM-2079-001_w.pdf - 第122页

1 19 SOM-2079 異常 ID 異常名、説明、要因および復帰方法 4b0c01 Nozzle Confirmation Error before Pick-up comp A component was detected on the nozzle before component pick-up. Please check placement state on placement step recovery screen. 4b…

100%1 / 179
118
SOM-2079
異常 ID 異常名、説明、要因および復帰方法
4b050f Manual Opn Error
Error was detected during operation.
-----
4b0601 Auto Run Start Error
Production operation has not started within predetermined time. (Please push a
start button again)
-----
4b0701 Communication Timeout
Communication failed to STG.#1 CPU
-----
4b0702 Communication Timeout
Communication failed to STG.#2 CPU
-----
4b0703 Communication Timeout
Communication failed to Recog CPU
-----
4b0704 Communication Timeout
Communication failed to STG CPU
-----
4b0705 Communication Timeout
The data could not be received in time.
-----
4b0706 Communication Timeout
Since the data could not be received in time, the pitch of the feeder was not
turned back.
Perform the feeder ready OFF and then, ON to return the feeder pitch.
4b0801 Linear measure operation is abnormal.
Linear measure was found abnormality while measuring.
-----
4b0802 Linear measure operation error
The measurement by the linear measure sensor was not completed on time.
-----
4b0803 Linear measure operation error
There is a problem in the values measured by the linear measure sensor.
-----
4b0901 Firmware Updating Timeout
Firmware update did not end in prescribed time.
-----
4b0a01 Feeder Alarm
Feeder Alarm. Please confi
rm the feeder and the component.
-----
4b0b01 Feeder base-main body connector unconnection
The connector on the feeder base-main body was disconnected. [B0916]
Please connect the connector on the feeder base to the main body, and press the
stage leady SW.
1005-001
6.11 その他
119
SOM-2079
異常 ID 異常名、説明、要因および復帰方法
4b0c01 Nozzle Confirmation Error before Pick-up comp
A component was detected on the nozzle before component pick-up.
Please check placement state on placement step recovery screen.
4b0c02 Nozzle Confirmation Error before Pick-up comp
Residual components were found in the nozzle while production operation.
Please confirm whether there is an error in the P.C.B.
4b0c03 Nozzle Confirmation Error before Pick-up comp
Abandonment is stopped because comp. had been detected on the nozzle.
Please confirm and clean up the nozzle if this error continues.
4b0c04 Nozzle Confirmation Error before Pick-up comp
A component was found on a nozzle after placement and it stayed on the nozzle
after release. Open the safety cover and check the nozzle. Then do Placement
recovery.
Please check placement state on placement step recovery screen.
4b0d01 Serial Out Mode Error
There was no response to the Serial Out Mode.
-----
4b0d02 Serial Out Mode Error
Communication failed to Shtg. of Comp. Host.
-----
4b0d03 Serial Out Mode Error
Communication with the Shtg. of Comp. Host has error.
-----
4b0e01 Splicing tape set error
The joint part of splicing tape is not correctly set. Please extract a feeder and
check whether the tape has separated from the guide.
-----
4b0f01 Decreasing of Comp. Hdlg. Rate
It stopped automatically by the rate fall of feeder adsorption.
-----
4b0f02 Decreasing of Comp. Hdlg. Rate
It stopped automatically by the rate fall of nozzle adsorption.
-----
4b1001 Flux spread error
The flux spread was not completed within prescribed time.
Please remove and check fl
ux spread equipment.
4b1101 Conveyance aging
Abnormalities occurred during PCB conveyance axis aging.
Please check motor, amplifier and unusual contents of servo. (NL-L axis, NA-L
axis, NB-L axis, NC-L axis, NR-L axis).
4b1102 Conveyance aging
The timeout occurred in conveyance axis operation during PCB conveyance axis
aging.
Please check motor, amplifier and unusual contents of servo. (NL-L axis, NA-L
axis, NB-L axis, NC-L axis, NR-L axis).
1005-001
6.11 その他
120
SOM-2079
異常 ID 異常名、説明、要因および復帰方法
4b1103 Conveyance aging
Abnormalities occurred during backup base axis aging.
Please check motor, amplifier and unusual contents of servo. (NA-B axis, NC-B
axis).
4b1104 Conveyance aging
The timeout occurred in backup base axis operation during backup base axis
aging.
Please check motor, amplifier and unusual contents of servo. (NA-B axis, NC-B
axis).
4b1105 Conveyance aging
Abnormalities occurred during Y arrangement shuttle axis aging.
Please check motor, amplifier and unusual contents of servo. (NL-W1 axis,
NL-W2 axis, NR-W1 axis, NR-W2 axis).
4b1106 Conveyance aging
The timeout occurred in Y arrangement shuttle axis operation during Y
arrangement shuttle axis aging.
Please check motor, amplifier and unusual contents of servo. (NL-W1 axis,
NL-W2 axis, NR-W1 axis, NR-W2 axis).
4b1201 Press in error / Insertion error
There is an error with the component pressed in or Insertion
Open safety cover and confirm the component on P.C.B. Please remove it or
revise it
4b1301 Flux spread equipment error
Motor alarm was generated.
Please remove and check flux spread equipment.
4b1401 Flux auto reload timeout
Drum rotation movement was not completed within prescribed time.
-----
4b1402 Flux auto reload timeout
Flux automatic reload was not completed within prescribed time.
-----
4b1501 Flux shortage of supply
The number of dip times and the time of automatic running were beyond a set
value.
Please supply a flux.
4b1601 Flux auto reload error
There is an abnormality in the flux automatic reload.
-----
4b1701 Flux auto reload motion error
Flux automatic reload motion was not completed within prescribed number of
times.
(1) Please confirm flux in a syringe is not insuffi
ciency.
(2) Please confirm setting of the threshold of a flux residual quantity detection
sensor.
(3) Please confirm whether a flux is perfect to the tip of a tube.
1005-001