Board-Inverter-Operation-Manual-REV-F-2.pdf - 第24页

BI2000 Boa rd Invert er Manual Revision F / January 2022 Page 24 of 37 Fault Recovery 294B Several err ors can cau se a fault co nditio n: • 144B “Emergency Stop” i s enga ged • 145B The doo r is op en • 146B Low air pre…

100%1 / 37
BI2000 Board Inverter Manual
Revision F / January 2022
Page 23 of 37
Profile Naming
1. 140BUse the arrows on the screen or the “F1” and “ESC” button to scroll to the Setup-
Rename Profile screen.
2.
141BUse the + - Page icons or the F2 and F4 keys to scroll through the profile names.
You can have a maximum of 30 profiles.
59BFigure 20: Rename Profile
3. 142BSelect the name you want to change.
4.
143BThe keyboard will be shown, type the new name and select enter. The new name will
be saved. Profile names are limited to 15 characters.
BI2000 Board Inverter Manual
Revision F / January 2022
Page 24 of 37
Fault Recovery
294BSeveral errors can cause a fault condition:
144B“Emergency Stop” is engaged
145BThe door is open
146BLow air pressure (option)
147BBoard processing failure
148BHoming failure
295BThe sections below show examples of some errors. For a complete list of error messages,
refer to Section 4.3.
WARNING: If the “Emergency Stop” was engaged because of a system failure, do not
disengage the “Emergency Stop” button. Shutdown the system and have qualified
personnel repair the machine.
Board Removal
296BAfter a fault, if there is a board in the inverter it must be removed. There are two ways to
remove a board.
Manual Board Removal
1. 149BEngage the “Emergency Stop” Button.
2.
150BOpen the Door.
3.
151BUse your hand to rotate the roll cage, if necessary.
4.
152BSlide the board out of the conveyer.
Conveyor Board Removal
1. 153BGo to Manual mode.
2.
154BSet the conveyor direction to the necessary setting, either upstream or
downstream.
3.
155BSet the conveyor to on. The board will exit the conveyor in the set direction.
4.
156BTurn the conveyor off.
BI2000 Board Inverter Manual
Revision F / January 2022
Page 25 of 37
Open Door or “Emergency Stop” Recovery
Procedure
297BIf the “Emergency Stop” button is engaged or there is a machine error, do this procedure.
Do not continue if the “Emergency Stop” was engaged because of a system failure
instead, shutdown the system and have it repaired by qualified personnel.
1.
157BDisengage the Emergency Stop” button or close the doors as necessary.
60BFigure 21: Emergency Stop
2. 158BFollow the on-screen display, push thePOWER ON” button to restore control power.
3.
159BOperate the system as normal.