BI2000 Boa rd Invert er Manual Revision F / January 2022 Page 34 of 37 T roubleshooting 73B Troubleshooting Problem 74B Possible C ause 75B Corrective A ction 0B The machine is On an d the operator interface has no power…

BI2000 Board Inverter Manual
Revision F / January 2022
Page 33 of 37
Main Air Regulator
• 201BMake sure there is no water in the bottom, drain as necessary.
72BFigure 33: Main Air Regulator

BI2000 Board Inverter Manual
Revision F / January 2022
Page 34 of 37
Troubleshooting
73B
Troubleshooting
Problem
74B
Possible Cause
75B
Corrective Action
0B
The machine is
On and the
operator
interface has no
power
•
1BCables are loose or not
connected
• 2BA fuse is blown
•
3BExamine the cable connections
and tighten loose connections
• 4BCheck the FU-1 fuse in the
electrical enclosure
5BBoard does not
transfer to or
from adjacent
station
•
6BThe SMEMA
connection is broken
• 7BA module in the line
is turned off
• 8BA fuse is blown
•
9BExamine the cable connections
and tighten loose connections
• 10BTurn the module on
• 11BCheck fuses FU-3 and FU-4 in
the electrical enclosure
12BThe part-in-place
sensor fails
•
13BA cable is loose or not
connected
• 14BThe sensor is positioned
incorrectly
•
15BThe sensor is out of
adjustment
•
16BExamine the cable connections
and tighten loose connections
• 17BMove the sensor
•
18BAdjust the sensor
19BConveyor does
not operate or
communication
error
•
20BConveyor belt stuck to
rails
• 21BChain does not operate
smoothly
• 22BCable is loose or not
connected
• 23BControl relay not on, or
Power On light not on
• 24BA fuse is blown
•
25BClean or replace belt
• 26BApply lubricant to the chain
• 27BExamine the cable connections
and tighten loose connections
• 28BCheck the system voltage and
electrical connections
• 29BCheck fuses FU-10 and FU-11 in
the electrical enclosure
30BPneumatic
position failure
•
31BNo air pressure
• 32BThe air lines are kinked
or torn
•
33BThe sensor is positioned
incorrectly
•
34BThe position sensor is
out of adjustment
•
35BThe rotary is out of
adjustment
•
36BMake sure main air regulator and
main air are both “On” and have
pressure
• 37BRepair or replace the lines
•
38BReplace the sensor
•
39BMove the sensor
•
40BAdjust the rotary