Board-Inverter-Operation-Manual-REV-F-2.pdf - 第26页
BI2000 Boa rd Invert er Manual Revision F / January 2022 Page 26 of 37 Recover y P rocedu re f or Boa rd P roces sing Fa ilure 299B A board proce ssing fail ure can resu lt fr om a board jam, or if th e bo ard i s lon ge…

BI2000 Board Inverter Manual
Revision F / January 2022
Page 25 of 37
Open Door or “Emergency Stop” Recovery
Procedure
297BIf the “Emergency Stop” button is engaged or there is a machine error, do this procedure.
Do not continue if the “Emergency Stop” was engaged because of a system failure
instead, shutdown the system and have it repaired by qualified personnel.
1.
157BDisengage the “Emergency Stop” button or close the doors as necessary.
60BFigure 21: Emergency Stop
2. 158BFollow the on-screen display, push the “POWER ON” button to restore control power.
3.
159BOperate the system as normal.

BI2000 Board Inverter Manual
Revision F / January 2022
Page 26 of 37
Recovery Procedure for Board Processing Failure
299BA board processing failure can result from a board jam, or if the board is longer than the
inverter can handle and the infeed and outfeed sensor are on at the same time.
2.
161BRemove the board.
61BFigure 22: Board Processing Failure
3. 162BWhen the Cycle Stop screen is shown, operate normally.
Recovery Procedure for a Rotation Error
301BWhen the roll cage cannot do a complete rotation (180°) there is a Rotation Error. This can be
caused by low air pressure.
2.
164BRemove the board.
3.
165BWhen the Cycle Stop screen is shown, operate normally.
62BFigure 23: Rotation Errors
4. 166BIf you continue to have this error, make sure the air pressure is in the necessary range.

BI2000 Board Inverter Manual
Revision F / January 2022
Page 27 of 37
Error Messages
303BThe following are all the possible error messages generated by the PLC program.
76B
MSG #
400BDescription
304B
0
305B
Disengage Emergency Stop
306B0a 307BClose Door (*If Door Bypass Off)
308B
1
309B
Rotate 0 Failure: Remove Board
310B2 311BRotate 180 Failure: Remove Board
312B
3
313B
Board Stop Did Not Extend
314B4 315BBoard Stop Did Not Retract
316B
5
317B
Board Failed to Reach Stops
318B6 319BInlet Shutter Failed to Open
320B
7
321B
Inlet Shutter Failed to Close
322B8 323BOutlet Shutter Failed to Open
324B
9
325B
Outlet Shutter Failed to Close
326B10 327BConveyor Adjust Drive Fault
63BFigure 24: Error Messages