SIPLACE S-23 HM.pdf - 第163页
User Manual SIPLAC E S-23 HM 5 Single Functions Software Version SR.406.xx 02/00 US Edition 5.2 Single functions, Gantry 163 5.2.4.1 Functions In the "Noz zle offset" screen only the "Meas ure" but to…

5 Single Functions User Manual SIPLACE S-23 HM
5.2 Single functions, Gantry Software Version SR.406.xx 02/00 US Edition
162
5.2.4 "Nozzle offset" screen
5
Å In the current screen for the single functions for Gantry x, click the symbol .
The user interface is switched to the "Nozzle offset" screen (see Fig. 5.2 - 4).
5
Fig. 5.2 - 4 "Nozzle offset" screen
User Manual SIPLACE S-23 HM 5 Single Functions
Software Version SR.406.xx 02/00 US Edition 5.2 Single functions, Gantry
163
5.2.4.1 Functions
In the "Nozzle offset" screen only the "Measure" button is available. This is used to start a evalu-
ation of the nozzle height for all nozzles.
Measure 5
When this function is activated, after a vacuum check the gantry moves the placement head to a
defined position above the board conveyor. The z-axis is lowered until the nozzle touches the con-
veyor, the procedure is then repeated for each nozzle. In this way, you can measure the height of
each nozzle.
The gantry then returns to its starting position. 5
Å Click the Measure button.
This starts the procedure used to measure nozzle height.
The values determined are displayed in the column "Offset (1/100 mm)" for each of the noz-
zles. These values can, for example, be used to determine whether the nozzle on a particular
segment broken.

5 Single Functions User Manual SIPLACE S-23 HM
5.2 Single functions, Gantry Software Version SR.406.xx 02/00 US Edition
164
5.2.5 "Nozzle configuration revolver head" screen
5
Å In the current screen for the single functions for Gantry x, click the symbol .
The user interface is switched to the "Nozzle configuration revolver head" screen (see Fig. 5.2 - 6).
5
Fig. 5.2 - 5 "Nozzle configuration revolver head" screen
5
Key to Fig. 5.2 - 5
(1) The entry for the segment currently located in the changeover position is highlighted in light
blue.
(2) The arrow points to the number of the segment which is in the changeover position.
5
1 2