11.8 Fine calibration
11.8.1 Overview
Fine calibration involves measuring the machine’s placement offset and determining the required
correction from this value. The ‘Fine calibration’ measuring program is integrated into the SITEST
program, and a detailed description of the measuring procedure is given in the ‘Fine calibration’
instructions (article no. 00191655-01). 11
CAUTION
The SITEST program is password-protected. It must only be called up and used by Siemens en-
gineers or appropriately trained personnel. 11
11.8.2 System requirements
The following system requirements must be fulfilled in order to use the fine calibration program:11
Machine type S2x, F
4 or later
Station computer software version 406.xx or later
SITEST version 406.xx or later
11.8.3 Measuring equipment and tools
The following are supplied as standard: 11
– Mapping plate (glass plate in a metal frame)
– Double-sided transparent adhesive film
– Lighting unit
– Magazine with glass components for the revolver head and Pick&Place head with fine-pitch
vision module.
11
The following items must be ordered: 11
– Manual tray (waffle tray holder) to hold the magazine for the glass components
(article number 00116430-xx)
11
11
User Manual SIPLACE S-23 HM 11 Station extensions / hardware
Software Version SR.406.xx 02/00 US Edition 11.8 Fine calibration
415
The following parts may be ordered if required: 11
– Magazine with glass components for the revolver head and Pick&Place head with flip-chip vi-
sion module (article number 00343704-xx)
11.8.4 Functional description
First select the placement program for fine calibration by selecting the ‘Cluster for fine calibration’
option from the ‘Options’ pull-down menu. Then process the mapping plate with the glass compo-
nents from a magazine on the manual tray. 11
After placement, start the SITEST program and start the ‘Fine calibration’ measuring program.
The placement head (revolver head or Pick&Place head) will measure the current placement po-
sitions of the glass components and compare these positions with the circular fiducials on the
mapping plate. The results are used to calculate the offset values. 11
The offset values are used to determine corrected values, which are then entered in the machine’s
machine data. 11
11
11
11 Station extensions / hardware User Manual SIPLACE S-23 HM
11.8 Fine calibration Software Version SR.406.xx 02/00 US Edition
416