SIPLACE S-23 HM.pdf - 第369页
User Manual SIPLAC E S-23 HM 10 Component han dling Software Version SR.406.xx 02/00 US Edition 10.2 Technical data for t he feeder modules 369 10.2.2 3 x 8 mm S module 10 Fig. 10.2 - 2 3 x 8 mm S module Item no. 0014109…

10 Component handling User Manual SIPLACE S-23 HM
10.2 Technical data for the feeder modules Software Version SR.406.xx 02/00 US Edition
368
10.2 Technical data for the feeder modules
The following pages contain diagrams of all the feeder modules, technical data and the module
setting options on the placement system. 10
10.2.1 8 mm S II module
10
Fig. 10.2 - 1 8 mm S II module
Item no. 00141096-xx
Width 30 mm
Tracks per module 2
Maximum number of modules 2 x 20
Magazine capacity for 7" reels Approx. 10000
Reel diameter 7" - 15" (up to 381 mm)
Feeding stroke (variable) 2mm / 4mm
Cycle time 60 ms
Main power supply 30 VDC

User Manual SIPLACE S-23 HM 10 Component handling
Software Version SR.406.xx 02/00 US Edition 10.2 Technical data for the feeder modules
369
10.2.2 3 x 8 mm S module
10
Fig. 10.2 - 2 3 x 8 mm S module
Item no. 00141098-xx
Width 30 mm
Tracks per module 3
Maximum number of modules 2 x 20
Magazine capacity for 7" reels Approx. 10,000
Reel diameter 7" - 15" (up to 381 mm)
Feeding stroke (variable) 2mm / 4mm
Cycle time 60 ms
Main power supply 30 VDC
LIMITED COMPONENT PICK-UP OPTIONS:
If the following combination of track, location and conveyor track is used, components cannot be
picked up from triple conveyors.
Location/Track Conveyor track
1/115 3
3/1 1 10

10 Component handling User Manual SIPLACE S-23 HM
10.2 Technical data for the feeder modules Software Version SR.406.xx 02/00 US Edition
370
10.2.3 3 x 8 mm S module for 0201/0402 components
Fig. 10.2 - 3 3x8mm S module for 0201/0402 components
Article number 00141099-xx
Width 30 mm
Component range 0201, 0402
Tracks per module 3
Maximum number of modules (DCA) 2 x 20
Stock of components for 7” reels approx. 10,000 – 15,000
Data specific to reel diameter 7” – 15”, maximum 381 mm
Transport distance (adjustable) 2mm ( 4mm)
Cycle time 60 ms
Power supply 30 V DC
LIMITED COMPONENT PICK-UP OPTIONS:
If the following combination of track, location and conveyor track is used, components cannot be
picked up from triple conveyors.
Location/Track Conveyor track
1/115 3
3/1 1 10