User Manual SIPLAC E S-23 HM 6 Vision functions Software Version SR.406.xx 02/00 US Edition 6.6 Test Component 247 6 Fig. 6.6 - 7 ’T est com ponent’ flow chart, ROW and CORNE R measure m ode menus’ ’ Test component’ menu…

100%1 / 454
6 Vision functions User Manual SIPLACE S-23 HM
6.6 Test Component Software Version SR.406.xx 02/00 US Edition
246
6
Fig. 6.6 - 6 ’Test component’ flow chart, SIZE measure mode menu
Test component’ menu options
SIZE measure mode’ menu
Cancel Accept
Resolution in direction
of integration
low
medium
high
very high
Resolution in
measurement direction
low
medium
high
very high
Integration
direction
In X direction
in Y direction
Resolution of
angle calculation
low
medium
high
very high
Method for calculation of
rotation
Automatic
selection
SWIN method
TWIN method
Integration settings of
SIZE meas. mode menu
User Manual SIPLACE S-23 HM 6 Vision functions
Software Version SR.406.xx 02/00 US Edition 6.6 Test Component
247
6
Fig. 6.6 - 7 ’Test component’ flow chart, ROW and CORNER measure mode menus’
Test component’ menu options
ROW measure mode’ and ’CORNER measure mode’ menus
ROW measure mode’ menu
CORNER measure mode’ menu
Tip measurement
via inner tips
Center
measurement
Tip measurement
via outer tips
Measurement
No. of pins to be measured
at each corner
One window
across the whole
lead window
No. of pins
at each corner
Cancel Accept
Angle measurement
activated
Yes/No
low
medium
high
very high
Resolution in
meas. direction
Resolution in
direction of
integration
low
medium
high
very high
Tip measurement
via inner tips
Center
measurement
Tip measurement
via outer tips
Measurement
Use package
form edges
For the
rotational
windows
For the
translational
windows
Cancel Accept
Cancel Accept
ROW measure mode’ menu -
integration settings
6 Vision functions User Manual SIPLACE S-23 HM
6.6 Test Component Software Version SR.406.xx 02/00 US Edition
248
6
Fig. 6.6 - 8 ’Test component’ flow chart, LEAD, GRID, and BALL meas. modes
Test component’ menu options
LEAD’, ’GRID’, and ’BALL’ measure mode menus
LEAD measure mode’ menu ’
Tip measurement
via inner tips
Center
measurement
Tip measurement
via outer tips
Measurement Window
Separately
for each pin
Combined
windows
Cancel Accept
Number of
balls to be
measured
Cancel Accept
Fast
Robust
Measurement Evaluation
Position
and
existance
Quality
Cancel Accept
GRID measure mode’ menu BALL measure mode’ menu