00196806-02_IM_EDM_1_10_en.pdf - 第31页

EDM V1.10 / Installation Manual 07/2011 Edition templateStorage Path L;M;D Storage location for application templates ( 5.2.3.23 ) transceiverClass Class L;M;C;T;D Class of data transfer ( 5.2.3.8 ) useAdvancedNotificati…

100%1 / 66
EDM V1.10 / Installation Manual 07/2011 Edition
incomingRequests Endpoint M;R Endpoint for incoming
queries to the master
(5.2.3.11)
machineAliasNames Section L;M;C;R Assignment of readable
names to the network IDs of
the individual EDM
computers (Line Servers,
Clearing Pool, etc.)
(5.2.3.31)
masterNotifications Endpoint L;R Destination for change
notifications (5.2.3.10)
masterRequests Endpoint L;C;R Requests to the Master
Server (5.2.3.9)
masterServer String L;M;C;R Network identification of the
Master Server (5.2.3.7)
notificationDistributorClass Class M;D Class for external
notifications (e.g. email)
notificationDistributor
ConfiguratorClass
Class M;D Configuration for external
notification system (e.g.
email) (5.2.3.4)
notificationInterval Time L;D Time to transfer the change
notification to the master
(5.2.3.5)
notificationStorage Endpoint L;D Temporary storage for
change notifications
responseTimeout Time L;D Timeout for replies from the
master (5.2.3.19)
requestCommandConfig Section M;R Scope of functionality of
Master Server (5.2.3.30)
serverType Enum L;M;C;R Operating mode of the
installation (5.2.3.1)
serviceRemotingEndpoint String L;R .NET remoting configuration
for communication with the
line service (5.2.3.22)
spiLines Section L SIPLACE Pro lines
associated with this Line
Server. (5.2.3.24)
startingPoints Section M List of permissible object
types for starting points
(5.2.3.28)
sqlDataSource String C;M;R SQL Server access for the
Clearing Pool (5.2.3.24)
sqlUserName String C;M;R User name for SQL Server
access (5.2.3.26)
sqlUserPassword String C;M;R Password for SQL Server
access (5.2.3.27)
30
EDM V1.10 / Installation Manual 07/2011 Edition
templateStorage Path L;M;D Storage location for
application templates
(5.2.3.23)
transceiverClass Class L;M;C;T;D Class of data transfer
(5.2.3.8)
useAdvancedNotification
Filtering
String
(true/false)
M;D Activate/deactivate direct
import/rejection of
notifications in the Master
Server (5.2.3.17)
useModifiedObjectProtection String
(true/false)
L;D Forced overwriting of
changed objects with older
master data (5.2.3.18)
useBlobExtension String
(true/false)
L;M;D Activates/deactivates EDM
VDM BLOB extensions
(5.2.3.32)
xmlImportVisionData
AdvancedAction
Integer L;M;C;D Sets the
VisionDataAdvancedAction
property of XmlImport.
Table 5-3: Contents of the configuration file
5.2.3.1 Server type
Key: serverType
Type: Enum
Values: LINE
MASTER
BOTH
CLEARINGPOOL
Valid for: Line server
Master server
Clearing pool
Description: Specifies the type of installation. The EDM server is started as a Line Server,
Master Server or hybrid depending on this setting (should only be used for test
purposes).
5.2.3.2 Help folder
Key: helpDirectory
Type: Path
Default: [AppDir]\help
Valid for: Line server
Master server
Clearing pool
EDM Tool
Description: Folder for online documentation
31
EDM V1.10 / Installation Manual 07/2011 Edition
5.2.3.3 Distribution list for EDM notifications
Key: notificationDistributorClass
Type: Class
Default: Siemens.SiplacePro.EDM.DataExchange.EmailDistributor,
DataExchange
Valid for: Master server
Description: Class, i.e. implementation of the notification service. At the present, distribution via
email is available using the default value as a reference.
5.2.3.4 Configuration of EDM notification traffic
Key: notificationDistributorConfiguratorClass
Type: Class
Default: Siemens.SiplacePro.EDM.UserInterface.EmailConfigurator,
UserInterface
Valid for: Master server
Description: Configuration dialog box for the notification service. The actual configuration of the
notification service depends on its implementation. Configuration of an email
service referenced using the default value is currently supported.
5.2.3.5 Notification interval
Key: notificationInterval
Type: Time
Default: P0Y0M0DT0H15M0S (= 15 minutes)
Valid for: Line server
Description: Time period during which the change notifications will be collected on the Line
Servers before they are sent to the Master Server. The other options are as follows
(from left to right):
Y = years
M = months
D = days
H = hours
M = minutes
S = seconds
The period should not be shorter than 5 minutes.
5.2.3.6 Notification storage
Key: notificationStorage
Type: Endpoint
Default: notificationStorage
Valid for: Line server
Description: Buffer for collected change notifications.
32