00196806-02_IM_EDM_1_10_en.pdf - 第34页

EDM V1.10 / Installation Manual 07/2011 Edition 5.2.3.11 Incoming requests Key: incomingRequests Type: Endpoint Valid for: Master server Description: Endpoint at which the Master Server lis tens in for incoming service r…

100%1 / 66
EDM V1.10 / Installation Manual 07/2011 Edition
5.2.3.7 Master server
Key: masterServer
Type: String
Valid for: Line server
Master server
Clearing pool
Description: Network ID of the Master Server. Windows computer name only. IP addresses are
not permitted.
5.2.3.8 Transceiver
Key: transceiverClass
Type: Class
Default: Siemens.SiplacePro.EDM.DataExchange.MsmqTransceiver,
DataExchange
Valid for: Line server
Master server
Clearing pool
EDM Tool
Description: Implements the data transfer between the Line Servers and Master Server. This
entry must be identical on all installed systems. The exact format of the "endpoint"
values depend on this value. The default setting uses MSMQ to transfer the data.
Endpoint: An endpoint entry has the following format for the MSMQ transceiver:
Private$\[queue-name].
Note that private queues absolutely must be used here. Only private queues can
be used in both a domain/active directory-based network environment as well as in
a pure workgroup installation.
5.2.3.9 Outgoing requests
Key: masterRequests
Type: Endpoint
Valid for: Line server
Clearing pool
Description: Target address for service requests sent by a Line Server to the Master Server.
The setting must be identical to the Incoming Requests setting on the Master
Server.
5.2.3.10 Outgoing change notifications
Key: masterNotifications
Type: Endpoint
Valid for: Line server
Description: Target address for change notifications sent by a Line Server to the Master Server.
The setting must be identical to the incoming change notifications setting on the
Master Server.
33
EDM V1.10 / Installation Manual 07/2011 Edition
5.2.3.11 Incoming requests
Key: incomingRequests
Type: Endpoint
Valid for: Master server
Description: Endpoint at which the Master Server listens in for incoming service requests.
Determines the value for outgoing requests on the Line Servers.
The value must be different from the value for incoming change notifications.
5.2.3.12 Incoming change notifications
Key: incomingNotifications
Type: Endpoint
Valid for: Master server
Description: Endpoint at which the Master Server listens in for incoming change notifications.
Determines the value for outgoing change notifications on the Line Servers.
The value must be different from the value for incoming requests.
5.2.3.13 Incoming Clearing Pool requests
Key: incomingClearingPoolRequests
Type: Endpoint
Valid for: Master server
Clearing pool
Description: Endpoint at which the Clearing Pool listens for incoming commands from the
master service.
5.2.3.14 EDM tool endpoint
Key: edmToolEndPoint
Type: Endpoint
Default: EDM_SPI_REMOTE_HOST:9002/EdmTool
Valid for: Master server
Line server
EDM Tool
Description: Endpoint for entering change notifications. The default value means that the
comment dialog boxes always open on the computer at which the SPI event was
triggered that caused the notification which requires a comment (if an EDM tool is
installed there).
If the line engineer is to enter the comments at a different computer, replace
EDM_SPI_REMOTE_HOST in the configuration file of the Line Server with the host
name of this computer.
34
EDM V1.10 / Installation Manual 07/2011 Edition
5.2.3.15 Endpoint configuration
Key: endpointConfig
Type: Section
Valid for: Master server
Description: This section contains pairs of values of the form:
<add key="[hostname]" value="[Endpoint]"/>
There is one pair of such values for each Line Server. This list describes the
connections from the Master Server to the Line Servers to be used.
The network ID (not the alias) of the computer concerned must be entered under
hostname. You can also enter "*" or "all" as the value for hostname. This is
then used as the default value when no entry can be found for a specific Line
Server.
Important: All Line Servers should always be listed in every configuration file. In
particular, the name of the local computer must be included (or at least an entry for
"*").
5.2.3.16 Communication timeout
Key: communicationTimeout
Type: Time
Default: P0Y0M0DT0H1M0S (= 1 minute)
Valid for: Line server
Master server
Clearing pool
Description: Time period in which a message must be received from a particular communication
partner. The setting should generally not be changed. The other options are as
follows (from left to right):
Y = years
M = months
D = days
H = hours
M = minutes
S = seconds
5.2.3.17 Use advanced EDM notification filtering
Key: useAdvancedNotificationFiltering
Type: String (true/false)
Default: true
Valid for: Master server
Description: Activation/deactivation of direct import/rejection of notifications by the Master
Server.
If these filters are deactivated, all notifications are entered in the Clearing Pool. If
they are activated, changes to objects can be accepted/rejected without first being
displayed in the Clearing Pool (for configuration, see section 5.4.3 Direct import of
changed objects to the master database and section 5.4.4 Automatic rejection of
the changes).
35