Host Computer System.pdf - 第102页
AVK3 HOST COMPUTER SYSTEM 3.10 Upl oading Rotary Chuck Inform a t ion D77HEC-54- 090-A0 3.10- 3 1) -5 D0F n T nnnnnnnnnnEnnnnnnnnnnI nnn nnnnnnn 1 2 3 4 5 Pnnnnnnnnnn Rnnnnnn Wn 6 7 8 No. Data name Max. digit s Input r…

AVK3
HOST COMPUTER SYSTEM
3.10 Uploading Rotary Chuck Information
D77HEC-54-090-A0
3.10-2
1) -3
D0EDnnnn / nn / nn nn : nn
1 2 3 4 5 6
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Collection end
date
2
×
Output command for the
production information
collection end date
2 Year (AD) 4 1991 to 2nnn
×
Corresponding to AD 2000
3 Month 2 01 to 12
×
4 Date 2 01 to 31
×
5 Hour 2 00 to 23
×
6 Minute 2 00 to 59
×
1) -4
D0HnTnnnnnnnnnnEnnnnnnnnnnInnnnnnnnnn
1 2 3 4 5
Pnnnnnnnnnn
RnnnnnnWn
6 7 8
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
26 mm chuck
command
1
×
Output command for the 26
mm rotary chuck information
2 Chuck No. 1 1 to 4
×
3
Parts chuck
count
10 0 to 999999999
×
4
Insertion error
count
10 0 to 999999999
×
5
No. of insertion
points
10 0 to 999999999
×
6
Parts remove
count
10 0 to 999999999
×
7 Insertion rate 6 0 to 100000
×
1 / 1000% increments
8
Maintenance
warning
1 0 to 1
×
0 = Insertion rate more than
99.01
1 = Insertion rate less than
99.00

AVK3
HOST COMPUTER SYSTEM
3.10 Uploading Rotary Chuck Information
D77HEC-54-090-A0
3.10-3
1) -5
D0FnTnnnnnnnnnnEnnnnnnnnnnInnnnnnnnnn
1 2 3 4 5
Pnnnnnnnnnn
RnnnnnnWn
6 7 8
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
52 mm chuck
command
1
×
Output command for the 52
mm rotary chuck information
2 Chuck No. 1 1 to 4
×
3
Parts chuck
count
10 0 to 999999999
×
4
Insertion error
count
10 0 to 999999999
×
5
No. of insertion
points
10 0 to 999999999
×
6
Parts remove
count
10 0 to 999999999
×
7 Insertion rate 6 0 to 100000
×
1 / 1000% increments
8
Maintenance
warning
1 0 to 1
×
0 = Insertion rate more than
99.01
1 = Insertion rate less than
99.00

AVK3
HOST COMPUTER SYSTEM
3.10 Uploading Rotary Chuck Information
D77HEC-54-090-A0
3.10-4
Protocol
Condition
Valid in ONLINE mode only.
After receiving ‘A2’ from HOST, the processing ends.
Start of upload
Host computer
Sends out rotary chuck
information.
AVK3
D 0 Collection start date
A 0
D 0
Collection end date
Requests next data.
A 0
A 0
D 0
∗
A 2
End of reception
End of transmission
C1R Total designation
A 0
D 0
Rotary chuck information
Sends out rotary chuck
information.
Sends out rotary chuck
information.
Requests next data.
Requests next data.
Sends out EOP data.