Host Computer System.pdf - 第38页
AVK3 HOST COMPUTER SYSTEM 2.4 Downloadi ng Indiv idual Machine Dat a D77HEC-52- 050A0 2.4- 7 1) - 17 D0RB X ( ± ) nnnnnn Y ( ± ) nnnnnn 1 2 3 No. Data name Max. digit s Input r ange Sup- press Vari- abl e Remarks 1 Rot…

AVK3
HOST COMPUTER SYSTEM
2.4 Downloading Individual Machine Data
D77HEC-52-050A0
2.4-6
1) - 14
D0CAX (±) nnnnnnY (±) nnnnnn
1 2 3
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1
Camera offset
command
2
× ×
Acknowledges as the set data
of camera offset.
When it is omitted, the
following data will be ignored.
2 X camera offset 7
-999999 to
+999999
Max. digit includes ±.
1 / 100 mm
3 Y camera offset 7
-999999 to
+999999
Max. digit includes ±.
1 / 100 mm
1) - 15
D0BAX (±) nnnnnnY (±) nnnnnn
1 2 3
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1
Bad mark offset
command
2
× ×
Acknowledges as the set data
of bad mark offset.
When it is omitted, the
following data will be ignored.
2
X bad mark
offset
7
-999999 to
+999999
Max. digit includes ±.
1 / 100 mm
3
Y bad mark
offset
7
-999999 to
+999999
Max. digit includes ±.
1 / 100 mm
1) - 16
D0RAX (±) nnnnnnY (±) nnnnnn
1 2 3
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1
Rotational offset
0° command
2
× ×
Acknowledges as the set data
of rotational offset 0°.
When it is omitted, the
following data will be ignored.
2 X direction offset 7
-999999 to
+999999
Max. digit includes ±.
1 / 100 mm
3 Y direction offset 7
-999999 to
+999999
Max. digit includes ±.
1 / 100 mm

AVK3
HOST COMPUTER SYSTEM
2.4 Downloading Individual Machine Data
D77HEC-52-050A0
2.4-7
1) - 17
D0RBX (±) nnnnnnY (±) nnnnnn
1 2 3
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1
Rotational offset
90° command
2
× ×
Acknowledges as the set data
of rotational offset 90°.
When it is omitted, the
following data will be ignored.
2 X direction offset 7
-999999 to
+999999
Max. digit includes ±.
1 / 100 mm
3 Y direction offset 7
-999999 to
+999999
Max. digit includes ±.
1 / 100 mm
1) - 18
D0RCX (±) nnnnnnY (±) nnnnnn
1 2 3
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1
Rotational offset
180° command
2
× ×
Acknowledges as the set data
of rotational offset 180°.
When it is omitted, the
following data will be ignored.
2 X direction offset 7
-999999 to
+999999
Max. digit includes ±.
1 / 100 mm
3 Y direction offset 7
-999999 to
+999999
Max. digit includes ±.
1 / 100 mm
1) - 19
D0RDX (±) nnnnnnY (±) nnnnnn
1 2 3
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1
Rotational offset
270° command
2
× ×
Acknowledges as the set data
of rotational offset 270°.
When it is omitted, the
following data will be ignored.
2 X direction offset 7
-999999 to
+999999
Max. digit includes ±.
1 / 100 mm
3 Y direction offset 7
-999999 to
+999999
Max. digit includes ±.
1 / 100 mm

AVK3
HOST COMPUTER SYSTEM
2.4 Downloading Individual Machine Data
D77HEC-52-050A0
2.4-8
1) - 20
D0DBP (±) nnnnnn
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1
Reference value
data command
2
× ×
Acknowledges as the set data
of reference value data.
When it is omitted, the
following data will be ignored.
2 PCB thickness 7
-999999 to
+999999
Max. digit includes ±.
(Fundamentally, in + direction
only)
1 / 100 mm
1) - 21
D0ILAn
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1
Interlock
command
2
× ×
Acknowledges as the set data
of interlock.
When it is omitted, the
following data will be ignored.
2 Interlock 1 0 to 2
×
0 = Interlock 1
1 = Interlock 2
2 = Interlock 3
=REMARKS=
If the data of 2 is out of the effective range, ‘A4E01’ is returned.
1) - 22
D0TAAnBnCnDn
1 2 3 4 5
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1
Rotary 26 mm
chuck command
2
× ×
Acknowledges as the set data
of rotary 26 mm chuck.
When it is omitted, the
following data will be ignored.
2 Rotary chuck 1 1 0 to 1
×
0 = Valid, 1 = Invalid
3 Rotary chuck 2 1 0 to 1
×
0 = Valid, 1 = Invalid
4 Rotary chuck 3 1 0 to 1
×
0 = Valid, 1 = Invalid
5 Rotary chuck 4 1 0 to 1
×
0 = Valid, 1 = Invalid
=REMARKS=