Host Computer System.pdf - 第95页
AVK3 HOST COMPUTER SYSTEM 3.8 Upl oadi ng Da t a Inf ormation D77HEC-54- 050-A0 3.8- 4

AVK3
HOST COMPUTER SYSTEM
3.8 Uploading Data Information
D77HEC-54-050-A0
3.8-3
Protocol
Condition
Can be used in standard specification.
Valid in ONLINE mode only.
After receiving ‘A2’ from HOST, the processing ends.
This information is held in each program. The information to be output will be the information of the
executing program.
Start of upload
Host computer
Sends out data
information.
AVK3
D 0 Collection start date
A 0
D 0
Collection end date
Requests next data.
A 0
A 0
D 0
∗
A 2
End of reception
End of transmission
C1D Total designation
A 0
D 0
Data information data

AVK3
HOST COMPUTER SYSTEM
3.8 Uploading Data Information
D77HEC-54-050-A0
3.8-4

AVK3
HOST COMPUTER SYSTEM
3.9 Uploading Feeder Information
D77HEC-54-040-A0
3.9-1
3.9. Uploading Feeder Information
D77HEC-54-040-A0
3.9.1 Uploading Feeder Information
With AVK3, if host computer gives C1 command to AVK3, the AVK3 becomes the receiving mode of the
internal feeder information and then can read the feeder information (using C1 command) sent to the AVK3.
Data details
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1 Total designation 3 000 to 900
×
=000: Sub-total
(no clear after upload)
=900: Grand total
(clear after upload)
(≠900 is sub-total)
AVK3 ⇒ Host computer
1) -1
D0SDnnnn / nn / nn nn : nn
1 2 3 4 5 6
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Collection start
date
2
×
Output command for the
production information
collection start date
2 Year (AD) 4 1991 to 2nnn
×
Corresponding to AD 2000
3 Month 2 01 to 12
×
4 Date 2 01 to 31
×
5 Hour 2 00 to 23
×
6 Minute 2 00 to 59
×
STX
C 1 Z x
No. of
characters
ETX
1
x x
Check sum
STX
D 0
No. of
characters
ETX
Check sum
1) -1 to 3