Host Computer System.pdf - 第121页

AVK3 HOST COMPUTER SYSTEM 4.4 MMC U nit Me mory Mo nitoring D77HEC-55- 340-A0 4.4- 2  Protocol  Condition  Can be used in standar d specif icati on.  Vali d i n O NLINE and O FFLI NE modes.  If unavail able address …

100%1 / 174
AVK3
HOST COMPUTER SYSTEM
4.4 MMC Unit Memory Monitoring
D77HEC-55-340-A0
4.4-1
4.4. MMC Unit Memory Monitoring
D77HEC-55-340-A0
4.4.1 MMC Unit Memory Monitoring
Monitoring is carried out by the byte unit. When the host computer gives the necessary address to AVK3, the
address status is returned from the AVK3 to the host computer.
However, even if the monitoring is commanded from the host computer while AVK3 is returning to the origin
of X-Y-Z axes, the program is not executed. The monitoring is executed only after completion of origin
return.
Data details
No. Data name
Max.
digits
Input range Omit
Vari-
able
Remarks
1
MMC unit
memory
command
2
× ×
Recognizes as the input
command of MMC memory.
2
Monitoring
address
5 00000 to FFFFF
×
AVK3 Host computer
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Monitoring
address
5 00000 to FFFFF
×
2 Monitoring result 4 0000 to FFFF
×
Outputs the monitored result
in hexadecimal.
STX
C 2 N M
No. of
characters
ETX
1
Monitoring
address
2
STX
D 0
No. of
characters
Address
ETX
1 2
Check sum
Monitoring
result
H
AVK3
HOST COMPUTER SYSTEM
4.4 MMC Unit Memory Monitoring
D77HEC-55-340-A0
4.4-2
Protocol
Condition
Can be used in standard specification.
Valid in ONLINE and OFFLINE modes.
If unavailable address is designated, returns all data as zeros.
Start of monitoring
End of transmission
Host computer
Sends out monitoring
data.
End of reception
AVK3
C2NM Address
D0 Address
A2
Data
AVK3
HOST COMPUTER SYSTEM
4.5 MMI Unit Input/Output Monitoring
D77HEC-55-350-A0
4.5-1
4.5. MMI Unit Input/Output Monitoring
D77HEC-55-350-A0
4.5.1 MMI Unit Input/Output Monitoring
Monitoring is carried out by the byte unit. When the host computer gives the necessary address to AVK3, the
address status is returned from the AVK3 to the host computer.
However, even if the monitoring is commanded from the host computer while AVK3 is returning to the origin
of X-Y-Z axes, the program is not executed. The monitoring is executed only after completion of origin
return.
Data details
No. Data name
Max.
digits
Input range Omit
Vari-
able
Remarks
1
MMI unit
input/output
command
2
× ×
Recognizes as the input
command of MMI input/output.
2
Monitoring
address
5 00000 to FFFFF
×
Most signification digit
= 0: Input, = 1: Output
AVK3 Host computer
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Monitoring
address
5
00000 to
1FFFF
×
2 Monitoring result 4 0000 to FFFF
×
Outputs the monitored result
in hexadecimal.
STX
C 2 I I
No. of
characters
ETX
1
Monitoring
address
2
STX
D 0
No. of
characters
Address
ETX
1 2
Check sum
Monitoring
result
H