Host Computer System.pdf - 第89页

AVK3 HOST COMPUTER SYSTEM 3.7 Upl oadi ng Pr oduction I nform at i on (NC) D77HEC-54- 080-A0 3.7- 4  1) -12 D0TE nnnnnnnnn 1 2 No. Data name Max. digit s Input r ange Sup- press Fi x Remarks 1 To tal in s ert ion error …

100%1 / 174
AVK3
HOST COMPUTER SYSTEM
3.7 Uploading Production Information (NC)
D77HEC-54-080-A0
3.7-3
1) -7
D0TRnnnnnn
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Total insertion
rate command
2
×
Output command for the total
insertion rate
2
Total insertion
rate
6 0 to 100000
×
1 / 1000% increments
1) -8
D0IRnnnnnn
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Insertion rate
command
2
×
Output command for the
insertion rate
2 Insertion rate 6 0 to 100000
×
1 / 1000% increments
1) -9
D0ICnnnnnnnnn
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Insertion count
command
2
×
Output command for the
Insertion count
2 Insertion count 9 0 to 999999999
×
1) -10
D0IEnnnnnnnnn
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Insertion error
count command
2
×
Output command for the
Insertion error count
2
Insertion error
count
9 0 to 999999999
×
1) -11
D0REnnnnnnnnn
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Recovery error
count command
2
×
Output command for the
recovery error count
2
Recovery error
count
9 0 to 999999999
×
AVK3
HOST COMPUTER SYSTEM
3.7 Uploading Production Information (NC)
D77HEC-54-080-A0
3.7-4
1) -12
D0TEnnnnnnnnn
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Total insertion
error count
command
2
×
Output command for the total
insertion error count
2
Total insertion
error count
9 0 to 999999999
×
1) -13
D0LEnnnnnnnnn
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Variable Remarks
1
Transfer error
count command
2
×
Output command for the
transfer error count
2
Transfer error
count
9
0 to
999999999
×
1) -14
D0ESnnnnnnnnn
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Error stop count
command
2
×
Output command for the error
stop count
2 Error stop count 9 0 to 999999999
×
1) -15
D0PEnnnnnnnnn
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Parts exhaust
count command
2
×
Output command for the parts
exhaust count
2
Parts exhaust
count
9 0 to 999999999
×
AVK3
HOST COMPUTER SYSTEM
3.7 Uploading Production Information (NC)
D77HEC-54-080-A0
3.7-5
Protocol
Condition
Can be used in standard specification.
Valid in ONLINE mode only.
After receiving ‘A2’ from HOST, the processing ends.
This information is held in each program. The information to be output will be the information of the
executing program.
Start of upload
Host computer
Sends out production
information (NC).
AVK3
D 0 Collection start date
A 0
D 0
Collection end date
Requests next data.
Sends out production
information (NC).
A 0
Requests next data.
A 0
D 0
A 2
End of reception
End of transmission
C1N Total designation
A 0
D 0
Production information data
Requests next data.
Sends out production
information (NC).
Sends out EOP data.