Host Computer System.pdf - 第97页

AVK3 HOST COMPUTER SYSTEM 3.9 Upl oadi ng F eeder Inf ormation D77HEC-54- 040-A0 3.9- 2  1) -2 D0ED nnnn / nn / n n n n : nn 1 2 3 4 5 6 No. Data name Max. digit s Input r ange Sup- press Fi x Remarks 1 Coll ecti on end…

100%1 / 174
AVK3
HOST COMPUTER SYSTEM
3.9 Uploading Feeder Information
D77HEC-54-040-A0
3.9-1
3.9. Uploading Feeder Information
D77HEC-54-040-A0
3.9.1 Uploading Feeder Information
With AVK3, if host computer gives C1 command to AVK3, the AVK3 becomes the receiving mode of the
internal feeder information and then can read the feeder information (using C1 command) sent to the AVK3.
Data details
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1 Total designation 3 000 to 900
×
=000: Sub-total
(no clear after upload)
=900: Grand total
(clear after upload)
(900 is sub-total)
AVK3 Host computer
1) -1
D0SDnnnn / nn / nn nn : nn
1 2 3 4 5 6
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Collection start
date
2
×
Output command for the
production information
collection start date
2 Year (AD) 4 1991 to 2nnn
×
Corresponding to AD 2000
3 Month 2 01 to 12
×
4 Date 2 01 to 31
×
5 Hour 2 00 to 23
×
6 Minute 2 00 to 59
×
STX
C 1 Z x
No. of
characters
ETX
1
x x
Check sum
STX
D 0
No. of
characters
ETX
Check sum
1) -1 to 3
AVK3
HOST COMPUTER SYSTEM
3.9 Uploading Feeder Information
D77HEC-54-040-A0
3.9-2
1) -2
D0EDnnnn / nn / nn nn : nn
1 2 3 4 5 6
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Collection end
date
2
×
Output command for the
production information
collection end date
2 Year (AD) 4 1991 to 2nnn
×
Corresponding to AD 2000
3 Month 2 01 to 12
×
4 Date 2 01 to 31
×
5 Hour 2 00 to 23
×
6 Minute 2 00 to 59
×
1) -3
D0ZnnnSnnnnnnnRnnnnnnnInnnnnnnnn
1 2 3 4
Ennnnnnnnn
PnnnnnnNnnn
5 6 7
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1 Z axis No. 3 1 to 080
×
2 Set parts number 7 0 to 9999999
×
3 Parts remainder 7 0 to 9999999
×
4
No. of insertion
points
9 0 to 999999999
×
5
Insertion error
count
9 0 to 999999999
×
6 Insertion rate 6 0 to 100000
×
1 / 1000% increments
7
Parts exhaust
count
3 1 to 999
×
AVK3
HOST COMPUTER SYSTEM
3.9 Uploading Feeder Information
D77HEC-54-040-A0
3.9-3
Protocol
Condition
Can be used in standard specification.
Valid in ONLINE mode only.
After receiving ‘A2’ from HOST, the processing ends.
Start of upload
Host computer
Sends out feeder
information.
AVK3
D 0 Collection start date
A 0
D 0
Collection end date
Requests next data.
A 0
A 0
D 0
A 2
End of reception
End of transmission
C1Z Total designation
A 0
D 0
Feeder information data
Sends out feeder
information.
Sends out feeder
information.
Requests next data.
Requests next data.