Host Computer System.pdf - 第41页

AVK3 HOST COMPUTER SYSTEM 2.4 Downloadi ng Indiv idual M achi ne Dat a D77HEC-52- 050A0 2.4- 10  1) - 26 D0CN A( ± )nnnnn 1 2 No. Data name Max. digit s Input r ange Sup- press Vari- abl e Remarks 1 Cam era angle comm a…

100%1 / 174
AVK3
HOST COMPUTER SYSTEM
2.4 Downloading Individual Machine Data
D77HEC-52-050A0
2.4-9
1) - 23
D0TBAnBnCnDn
1 2 3 4 5
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1
Rotary 52 mm
chuck command
2
× ×
Acknowledges as the set data
of rotary 52 mm chuck.
When it is omitted, the
following data will be ignored.
2 Rotary chuck 1 1 0 to 1
×
0 = Valid, 1 = Invalid
3 Rotary chuck 2 1 0 to 1
×
0 = Valid, 1 = Invalid
4 Rotary chuck 3 1 0 to 1
×
0 = Valid, 1 = Invalid
5 Rotary chuck 4 1 0 to 1
×
0 = Valid, 1 = Invalid
=REMARKS=
If the data of 2 to 5 is out of the effective range, ‘A4E01’ is returned.
1) - 24
D0SC nn Tnnnnnn
1 2 3
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1
SC timer
command
2
× ×
Acknowledges as the set data
of SC timer.
When it is omitted, the
following data will be ignored.
2 Timer No. 1 01 to 48
×
Stores the data according to
SC timer No.
If over the input range, it will be
ignored.
3 Timer set value 6 0 to 999999
+ direction only.
ms
1) - 25
D0CSAnnnnBnnnn
1 2 3
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1
Camera scale
command
2
× ×
Acknowledges as the set data
of camera scale.
When it is omitted, the
following data will be ignored.
2 Camera scale X 4 6000 to 9000
×
Camera scale X
1 / 100 µm / pix
3 Camera scale Y 4 6000 to 9000
×
Camera scale Y
1 / 100 µm / pix
AVK3
HOST COMPUTER SYSTEM
2.4 Downloading Individual Machine Data
D77HEC-52-050A0
2.4-10
1) - 26
D0CNA(±)nnnnn
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1
Camera angle
command
2
× ×
Acknowledges as the set data
of camera angle.
When it is omitted, the
following data will be ignored.
2 Camera angle 6
-10000 to
10000
Camera angle
1 / 1000°
1) - 27
D0BIAnnn
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1
Binary level
command
2
× ×
Acknowledges as the set data
of binary level.
When it is omitted, the
following data will be ignored.
2
Camera binary
level
3 0 to 255
Camera binary level
1) - 28
D0YUAnnnnBnnnn
1 2 3
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1
Effective hole
diameter
command
2
× ×
Acknowledges as the set data
of effective hole diameter.
When it is omitted, the
following data will be ignored.
2
Min. hole
diameter
4 0 to 1000
×
Min. hole diameter
1 / 100 mm
3
Max. hole
diameter
4 0 to 1000
×
Max. hole diameter
1 / 100 mm
AVK3
HOST COMPUTER SYSTEM
2.4 Downloading Individual Machine Data
D77HEC-52-050A0
2.4-11
1) - 29
D0SAAnnnn
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1
Search area size
command
2
× ×
Acknowledges as the set data
of search area size.
When it is omitted, the
following data will be ignored.
2 Search area size 4 0 to 3000
×
The size of search area
1 / 100 mm
1) - 30
D0ISTnnn
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1
Search clear
interval
command
2
× ×
Acknowledges as the set data
of screen clear interval.
When it is omitted, the
following data will be ignored.
2 Time 3 0 to 255
×
Time (min)
1) - 31
D0AXAnBnCnDnEnFnGnHnInJnKnLn
1 2 3 4 5 6 7 8 9 10111213
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1
NC axis
valid/invalid
command
2
× ×
Acknowledges as the set data
of NC axis valid/invalid
command.
When it is omitted, the
following data will be ignored.
2 X axis 1 0 to 1
×
0 = Valid, 1 = Invalid
3 Y axis 1 0 to 1
×
0 = Valid, 1 = Invalid
4 ZL axis 1 0 to 1
×
0 = Valid, 1 = Invalid
5 ZR axis 1 0 to 1
×
0 = Valid, 1 = Invalid
6 T axis 1 0 to 1
×
0 = Valid, 1 = Invalid
7 U axis 1 0 to 1
×
0 = Valid, 1 = Invalid
8 H axis 1 0 to 1
×
0 = Valid, 1 = Invalid
9
θH axis
1 0 to 1
×
0 = Valid, 1 = Invalid
10
θA axis
1 0 to 1
×
0 = Valid, 1 = Invalid
11 WH axis 1 0 to 1
×
0 = Valid, 1 = Invalid
12 WA axis 1 0 to 1
×
0 = Valid, 1 = Invalid
13 V axis 1 0 to 1
×
0 = Valid, 1 = Invalid