Host Computer System.pdf - 第67页
AVK3 HOST COMPUTER SYSTEM 3.4 Upl oadi ng I ndiv idual Machine Dat a D77HEC-53- 050-A0 3.4- 6 1) -15 D0RA X ( ± ) nnnnnn Y ( ± ) nnnnnn 1 2 3 No. Data name Max. digit s Input r ange Sup- press Fi x Remarks 1 Rotat iona…

AVK3
HOST COMPUTER SYSTEM
3.4 Uploading Individual Machine Data
D77HEC-53-050-A0
3.4-5
1) -12
D0MTA (±) nnnnnnB (±) nnnnnnC (±) nnnnnnD (±) nnnnnn
1 2 3 4 5
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Rotary individual
offset command
2
×
Output command for the
rotary individual offset
2
Rotary chuck
1
7
-999999 to
+999999
×
Max. digit includes ±.
1 / 100°
3
Rotary chuck
2
7
-999999 to
+999999
×
Max. digit includes ±.
1 / 100°
4
Rotary chuck
3
7
-999999 to
+999999
×
Max. digit includes ±.
1 / 100°
5
Rotary chuck
4
7
-999999 to
+999999
×
Max. digit includes ±.
1 / 100°
1) -13
D0CAX (±) nnnnnnY (±) nnnnnn
1 2 3
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Camera offset
command
2
×
Output command for the
camera offset
2 X camera offset 7
-999999 to
+999999
×
Max. digit includes ±.
1 / 100 mm
3 Y camera offset 7
-999999 to
+999999
×
Max. digit includes ±.
1 / 100 mm
1) -14
D0BAX (±) nnnnnnY (±) nnnnnn
1 2 3
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Bad mark offset
command
2
×
Output command for the bad
mark offset
2
X bad mark
offset
7
-999999 to
+999999
×
Max. digit includes ±.
1 / 100 mm
3
Y bad mark
offset
7
-999999 to
+999999
×
Max. digit includes ±.
1 / 100 mm

AVK3
HOST COMPUTER SYSTEM
3.4 Uploading Individual Machine Data
D77HEC-53-050-A0
3.4-6
1) -15
D0RAX (±) nnnnnnY (±) nnnnnn
1 2 3
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Rotational offset
0° command
2
×
Output command for the
rotation offset 0°
2 X direction offset 7
-999999 to
+999999
×
Max. digit includes ±.
1 / 100 mm
3 Y direction offset 7
-999999 to
+999999
×
Max. digit includes ±.
1 / 100 mm
1) -16
D0RBX (±) nnnnnnY (±) nnnnnn
1 2 3
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Rotational offset
90° command
2
×
Output command for the
rotation offset 90°
2 X direction offset 7
-999999 to
+999999
×
Max. digit includes ±.
1 / 100 mm
3 Y direction offset 7
-999999 to
+999999
×
Max. digit includes ±.
1 / 100 mm
1) -17
D0RCX (±) nnnnnnY (±) nnnnnn
1 2 3
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Rotational offset
180° command
2
×
Output command for the
rotation offset 180°.
2 X direction offset 7
-999999 to
+999999
×
Max. digit includes ±.
1 / 100 mm
3 Y direction offset 7
-999999 to
+999999
×
Max. digit includes ±.
1 / 100 mm

AVK3
HOST COMPUTER SYSTEM
3.4 Uploading Individual Machine Data
D77HEC-53-050-A0
3.4-7
1) -18
D0RDX (±) nnnnnnY (±) nnnnnn
1 2 3
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Rotational offset
270° command
2
×
Output command for the
rotation offset 270°
2 X direction offset 7
-999999 to
+999999
×
Max. digit includes ±.
1 / 100 mm
3 Y direction offset 7
-999999 to
+999999
×
Max. digit includes ±.
1 / 100 mm
1) -19
D0DBP (±) nnnnnn
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Reference value
data command
2
×
Output command for the
reference value data
2 PCB thickness 7
-999999 to
+999999
×
Max. digit includes ±.
(Fundamentally, in + direction
only)
1 / 100 mm
1) -20
D0ITAn
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Interlock
command
2
×
Output command for the
interrupt data
2 Interlock 1 0 to 1
×
0 = Interlock 1,
1 = Interlock 2