Host Computer System.pdf - 第124页
AVK3 HOST COMPUTER SYSTEM 4.6 MMI Unit Mem ory Monitori ng D76HEC-55- 360-A0 4.6- 1 4.6. MMI Unit Memory Monitoring D76HEC - 55-360-A 0 4.6. 1 MMI Unit M emory M onitoring Monit oring is carried out by t he byte unit. W …

AVK3
HOST COMPUTER SYSTEM
4.5 MMI Unit Input/Output Monitoring
D77HEC-55-350-A0
4.5-2
Protocol
Condition
Can be used in standard specification.
Valid in ONLINE and OFFLINE modes.
If unavailable address is designated, returns all data as zeros.
Start of monitoring
End of transmission
Host computer
Sends out monitoring
data.
End of reception
AVK3
C2II Address
D0 Address
A2
Data

AVK3
HOST COMPUTER SYSTEM
4.6 MMI Unit Memory Monitoring
D76HEC-55-360-A0
4.6-1
4.6. MMI Unit Memory Monitoring
D76HEC-55-360-A0
4.6.1 MMI Unit Memory Monitoring
Monitoring is carried out by the byte unit. When the host computer gives the necessary address to AVK3, the
address status is returned from the AVK3 to the host computer.
However, even if the monitoring is commanded from the host computer while AVK3 is returning to the origin
of X-Y-Z axes, the program is not executed. The monitoring is executed only after completion of origin
return.
Data details
No. Data name
Max.
digits
Input range Omit
Vari-
able
Remarks
1
MMI unit
input/output
command
2
×
Recognizes as the input
command of MMI input/output.
2
Monitoring
address
5 00000 to FFFFF
×
AVK3 ⇒ Host computer
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Monitoring
address
5 00000 to FFFFF
×
2 Monitoring result 4 0000 to FFFF
×
Outputs the monitored result
in hexadecimal.
STX
C 2 I M
No. of
characters
ETX
1
Monitoring
address
2
STX
D 0
No. of
characters
Address
ETX
1 2
Check sum
Monitoring
result
H

AVK3
HOST COMPUTER SYSTEM
4.6 MMI Unit Memory Monitoring
D76HEC-55-360-A0
4.6-2
Protocol
Condition
Can be used in standard specification.
Valid in ONLINE and OFFLINE modes.
If unavailable address is designated, returns all data as zeros.
Start of monitoring
End of transmission
Host computer
Sends out monitoring
data.
End of reception
AVK3
C2IM Address
D0 Address
A2
Data