Host Computer System.pdf - 第39页

AVK3 HOST COMPUTER SYSTEM 2.4 Downloadi ng Indiv idual M achi ne Dat a D77HEC-52- 050A0 2.4- 8  1) - 20 D0DB P ( ± ) nnnnnn 1 2 No. Data name Max. digit s Input r ange Sup- press Vari- abl e Remarks 1 Ref erence v alue …

100%1 / 174
AVK3
HOST COMPUTER SYSTEM
2.4 Downloading Individual Machine Data
D77HEC-52-050A0
2.4-7
1) - 17
D0RBX (±) nnnnnnY (±) nnnnnn
1 2 3
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1
Rotational offset
90° command
2
× ×
Acknowledges as the set data
of rotational offset 90°.
When it is omitted, the
following data will be ignored.
2 X direction offset 7
-999999 to
+999999
Max. digit includes ±.
1 / 100 mm
3 Y direction offset 7
-999999 to
+999999
Max. digit includes ±.
1 / 100 mm
1) - 18
D0RCX (±) nnnnnnY (±) nnnnnn
1 2 3
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1
Rotational offset
180° command
2
× ×
Acknowledges as the set data
of rotational offset 180°.
When it is omitted, the
following data will be ignored.
2 X direction offset 7
-999999 to
+999999
Max. digit includes ±.
1 / 100 mm
3 Y direction offset 7
-999999 to
+999999
Max. digit includes ±.
1 / 100 mm
1) - 19
D0RDX (±) nnnnnnY (±) nnnnnn
1 2 3
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1
Rotational offset
270° command
2
× ×
Acknowledges as the set data
of rotational offset 270°.
When it is omitted, the
following data will be ignored.
2 X direction offset 7
-999999 to
+999999
Max. digit includes ±.
1 / 100 mm
3 Y direction offset 7
-999999 to
+999999
Max. digit includes ±.
1 / 100 mm
AVK3
HOST COMPUTER SYSTEM
2.4 Downloading Individual Machine Data
D77HEC-52-050A0
2.4-8
1) - 20
D0DBP (±) nnnnnn
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1
Reference value
data command
2
× ×
Acknowledges as the set data
of reference value data.
When it is omitted, the
following data will be ignored.
2 PCB thickness 7
-999999 to
+999999
Max. digit includes ±.
(Fundamentally, in + direction
only)
1 / 100 mm
1) - 21
D0ILAn
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1
Interlock
command
2
× ×
Acknowledges as the set data
of interlock.
When it is omitted, the
following data will be ignored.
2 Interlock 1 0 to 2
×
0 = Interlock 1
1 = Interlock 2
2 = Interlock 3
=REMARKS=
If the data of 2 is out of the effective range, ‘A4E01’ is returned.
1) - 22
D0TAAnBnCnDn
1 2 3 4 5
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1
Rotary 26 mm
chuck command
2
× ×
Acknowledges as the set data
of rotary 26 mm chuck.
When it is omitted, the
following data will be ignored.
2 Rotary chuck 1 1 0 to 1
×
0 = Valid, 1 = Invalid
3 Rotary chuck 2 1 0 to 1
×
0 = Valid, 1 = Invalid
4 Rotary chuck 3 1 0 to 1
×
0 = Valid, 1 = Invalid
5 Rotary chuck 4 1 0 to 1
×
0 = Valid, 1 = Invalid
=REMARKS=
If the data of 2 to 5 is out of the effective range, ‘A4E01’ is returned.
AVK3
HOST COMPUTER SYSTEM
2.4 Downloading Individual Machine Data
D77HEC-52-050A0
2.4-9
1) - 23
D0TBAnBnCnDn
1 2 3 4 5
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1
Rotary 52 mm
chuck command
2
× ×
Acknowledges as the set data
of rotary 52 mm chuck.
When it is omitted, the
following data will be ignored.
2 Rotary chuck 1 1 0 to 1
×
0 = Valid, 1 = Invalid
3 Rotary chuck 2 1 0 to 1
×
0 = Valid, 1 = Invalid
4 Rotary chuck 3 1 0 to 1
×
0 = Valid, 1 = Invalid
5 Rotary chuck 4 1 0 to 1
×
0 = Valid, 1 = Invalid
=REMARKS=
If the data of 2 to 5 is out of the effective range, ‘A4E01’ is returned.
1) - 24
D0SC nn Tnnnnnn
1 2 3
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1
SC timer
command
2
× ×
Acknowledges as the set data
of SC timer.
When it is omitted, the
following data will be ignored.
2 Timer No. 1 01 to 48
×
Stores the data according to
SC timer No.
If over the input range, it will be
ignored.
3 Timer set value 6 0 to 999999
+ direction only.
ms
1) - 25
D0CSAnnnnBnnnn
1 2 3
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1
Camera scale
command
2
× ×
Acknowledges as the set data
of camera scale.
When it is omitted, the
following data will be ignored.
2 Camera scale X 4 6000 to 9000
×
Camera scale X
1 / 100 µm / pix
3 Camera scale Y 4 6000 to 9000
×
Camera scale Y
1 / 100 µm / pix