Host Computer System.pdf - 第70页

AVK3 HOST COMPUTER SYSTEM 3.4 Upl oading Indivi dual Machine Dat a D77HEC-53- 050-A0 3.4- 9  1) -24 D0CS AnnnnB nnnn 1 2 3 No. Data name Max. digit s Input r ange Sup- press Fi x Remarks 1 Cam era scale comm and 2 ×  …

100%1 / 174
AVK3
HOST COMPUTER SYSTEM
3.4 Uploading Individual Machine Data
D77HEC-53-050-A0
3.4-8
1) -21
D0TAAnBnCnDn
1 2 3 4 5
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Rotary 26 mm
chuck command
2
×
Output command for the
rotary 26 mm chuck
2 Rotary chuck 1 1 0 to 1
×
0 = Valid, 1 = Invalid
3 Rotary chuck 2 1 0 to 1
×
0 = Valid, 1 = Invalid
4 Rotary chuck 3 1 0 to 1
×
0 = Valid, 1 = Invalid
5 Rotary chuck 4 1 0 to 1
×
0 = Valid, 1 = Invalid
1) -22
D0TBAnBnCnDn
1 2 3 4 5
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Rotary 52 mm
chuck command
2
×
Output command for the
rotary 52 mm chuck
2 Rotary chuck 1 1 0 to 1
×
0 = Valid, 1 = Invalid
3 Rotary chuck 2 1 0 to 1
×
0 = Valid, 1 = Invalid
4 Rotary chuck 3 1 0 to 1
×
0 = Valid, 1 = Invalid
5 Rotary chuck 4 1 0 to 1
×
0 = Valid, 1 = Invalid
1) -23
D0SCnnTnnnnnn
1 2 3
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
SC timer
command
2
×
Output command for the SC
timer
2 Timer No. 2 01 to 48
×
SC timer No.
3 Timer set value 6 0 to 999999
×
+ direction only
ms
AVK3
HOST COMPUTER SYSTEM
3.4 Uploading Individual Machine Data
D77HEC-53-050-A0
3.4-9
1) -24
D0CSAnnnnBnnnn
1 2 3
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Camera scale
command
2
×
Output command for the
camera scale
2 Camera scale X 4 6000 to 9000
×
Camera scale X
1 / 100 µm / pix
3 Camera scale Y 4 6000 to 9000
×
Camera scale Y
1 / 100 µm / pix
1) -25
D0CNA(±)nnnnn
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Camera angle
command
2
×
Output command for the
camera angle
2 Camera angle 6
-10000 to
10000
×
Camera angle
1 / 1000°
1) -26
D0BIAnnn
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Binary level
command
2
×
Output command for the
binary level
2
Camera binary
level
3 0 to 255
×
Camera binary level
1) -27
D0YUAnnnnBnnnn
1 2 3
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Effective hole
diameter
command
2
×
Output command for the
effective hole diameter
2
Min. hole
diameter
4 0 to 1000
×
Min. hole diameter
1 / 100 mm
3
Max. hole
diameter
4 0 to 1000
×
Max. hole diameter
1 / 100 mm
AVK3
HOST COMPUTER SYSTEM
3.4 Uploading Individual Machine Data
D77HEC-53-050-A0
3.4-10
1) -28
D0SAAnnnn
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Search area size
command
2
×
Output command for the
search area size
2 Search area size 4 0 to 3000
×
The size of search area
1 / 100 mm
1) -29
D0ISTnnn
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Search clear
interval
command
2
×
Output command for the
search clear interval
2 Time 3 0 to 255
×
Time (min)
1) -30
D0ABAnBnCnDnEnFnGnHnInJnKnLn
1 2 3 4 5 6 7 8 9 10111213
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
NC axis
valid/invalid
command
2
×
Output command for the NC
axis valid/invalid
2 X axis 1 0 to 1
×
0 = Valid, 1 = Invalid
3 Y axis 1 0 to 1
×
0 = Valid, 1 = Invalid
4 ZL axis 1 0 to 1
×
0 = Valid, 1 = Invalid
5 ZR axis 1 0 to 1
×
0 = Valid, 1 = Invalid
6 T axis 1 0 to 1
×
0 = Valid, 1 = Invalid
7 U axis 1 0 to 1
×
0 = Valid, 1 = Invalid
8 H axis 1 0 to 1
×
0 = Valid, 1 = Invalid
9
θH axis
1 0 to 1
×
0 = Valid, 1 = Invalid
10
θA axis
1 0 to 1
×
0 = Valid, 1 = Invalid
11 WH axis 1 0 to 1
×
0 = Valid, 1 = Invalid
12 WA axis 1 0 to 1
×
0 = Valid, 1 = Invalid
13 V axis 1 0 to 1
×
0 = Valid, 1 = Invalid