Host Computer System.pdf - 第65页

AVK3 HOST COMPUTER SYSTEM 3.4 Upl oadi ng I ndiv idual Machine Dat a D77HEC-53- 050-A0 3.4- 4  1) -10 D0MA X ( ± ) nnnnnn Y ( ± ) nnnnnnL ( ± ) nnnnnn 1 2 3 4 R( ± )nnnnn H ( ± ) nnnnnn A ( ± ) nnnnnn 5 6 7 No. Data nam…

100%1 / 174
AVK3
HOST COMPUTER SYSTEM
3.4 Uploading Individual Machine Data
D77HEC-53-050-A0
3.4-3
1) -6
D0RSFn
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Insertion error
non-clear
command
2
×
Command for the insertion
error non-clearing
2
Insertion error
non-clear
setting
1 0 to 1
×
Insertion error non-clear
setting
0 = Can be cleared with
“RESET”.
1 = Cannot be cleared with
“RESET”.
1) -7
D0RPnn
1 2
No. Data name
Max.
digits
Output range
Sup-
press
Fix Remarks
1
Command by
production count
2
×
Output command for the set
data by production count
2 Count 2 0 to 99
×
Setting by count
0 = Only once at the beginning
of model changeover
1 = Every time
2 = Every two boards
1) -8
D0ARnRnn
1 2 3
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Command by
production count
2
×
Output command for the
automatic recovery
2 Count 1 0 to 1
×
Recovery setting
0 = Valid, 1 = Invalid
3
Command by
production count
2 0 to 99
×
Recovery count
1) -9
D0DTDn
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Data type
command
2
×
Output command for the data
type
2 Data type 1 0 to 1
×
0 = ABS, 1 = INC
AVK3
HOST COMPUTER SYSTEM
3.4 Uploading Individual Machine Data
D77HEC-53-050-A0
3.4-4
1) -10
D0MAX (±) nnnnnnY (±) nnnnnnL (±) nnnnnn
1 2 3 4
R(±)nnnnn
H (±) nnnnnnA (±) nnnnnn
5 6 7
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Machine offset 1
command
2
×
Output command for the
machine offset 1
2 X offset 7
-999999 to
+999999
×
Max. digit includes ±.
1 / 100 mm
3 Y offset 7
-999999 to
+999999
×
Max. digit includes ±.
1 / 100 mm
4 ZL offset 7
-999999 to
+999999
×
Max. digit includes ±.
1 / 100 mm
5 ZR offset 7
-999999 to
+999999
×
Max. digit includes ±.
1 / 100 mm
6 WH offset 7
-999999 to
+999999
×
Max. digit includes ±.
1 / 100 mm
7 WA offset 7
-999999 to
+999999
×
Max. digit includes ±.
1 / 100 mm
1) -11
D0MBH (±) nnnnnnA (±) nnnnnn
1 2 3
T (±)nnnnnn
V (±) nnnnnnU (±) nnnnnn
4 5 6
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Machine offset 2
command
2
×
Output command for the
machine offset 2
2
θH offset
7
-999999 to
+999999
×
Max. digit includes ±.
1 / 100°
3
θA offset
7
-999999 to
+999999
×
Max. digit includes ±.
1 / 100°
4 T offset 7
-999999 to
+999999
×
Max. digit includes ±.
1 / 100°
5 V offset 7
-999999 to
+999999
×
Max. digit includes ±.
1 / 100°
6 U offset 7
-999999 to
+999999
×
Max. digit includes ±.
1 / 100°
AVK3
HOST COMPUTER SYSTEM
3.4 Uploading Individual Machine Data
D77HEC-53-050-A0
3.4-5
1) -12
D0MTA (±) nnnnnnB (±) nnnnnnC (±) nnnnnnD (±) nnnnnn
1 2 3 4 5
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Rotary individual
offset command
2
×
Output command for the
rotary individual offset
2
Rotary chuck
1
7
-999999 to
+999999
×
Max. digit includes ±.
1 / 100°
3
Rotary chuck
2
7
-999999 to
+999999
×
Max. digit includes ±.
1 / 100°
4
Rotary chuck
3
7
-999999 to
+999999
×
Max. digit includes ±.
1 / 100°
5
Rotary chuck
4
7
-999999 to
+999999
×
Max. digit includes ±.
1 / 100°
1) -13
D0CAX (±) nnnnnnY (±) nnnnnn
1 2 3
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Camera offset
command
2
×
Output command for the
camera offset
2 X camera offset 7
-999999 to
+999999
×
Max. digit includes ±.
1 / 100 mm
3 Y camera offset 7
-999999 to
+999999
×
Max. digit includes ±.
1 / 100 mm
1) -14
D0BAX (±) nnnnnnY (±) nnnnnn
1 2 3
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
Bad mark offset
command
2
×
Output command for the bad
mark offset
2
X bad mark
offset
7
-999999 to
+999999
×
Max. digit includes ±.
1 / 100 mm
3
Y bad mark
offset
7
-999999 to
+999999
×
Max. digit includes ±.
1 / 100 mm