AVK3 HOST COMPUTER SYSTEM 3.3 Upl oading P.C.B. Dat a D77HEC-53- 030-A1 3.3- 1 3.3. Uploading P.C.B. Data D77HEC - 53-030-A 1 3.3. 1 Uploadin g P . C.B. Data  Data details  1) -1 C1C ∗ - ∗ 1 No. Data name Max. digit s …

100%1 / 174
AVK3
HOST COMPUTER SYSTEM
3.2 Uploading Parts Data
D77HEC-53-110-A0
3.2-2
Protocol
Condition
Can be used in standard specification.
Valid in ONLINE mode only.
If a program which does not exist in the memory is specified, ‘A4E00’ is returned.
After receiving ‘A2’ from HOST, the processing ends.
Start of upload
Host computer
Sends out parts data.
AVK3
D 0 Parts data
A 0
C1U
Control No.:
3 digits
Program name (Up
to 12 characters)
D 0
Parts data
Requests next data.
A 0
Requests next data.
Sends out parts data.
Sends out EOP data.
A 0
D 0 Feeder No.
A 2
End of transmission
End of reception
AVK3
HOST COMPUTER SYSTEM
3.3 Uploading P.C.B. Data
D77HEC-53-030-A1
3.3-1
3.3. Uploading P.C.B. Data
D77HEC-53-030-A1
3.3.1 Uploading P.C.B. Data
Data details
1) -1
C1C -
1
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1 Program name 15
‘0’ to ‘9’
‘A’ to ‘Z
Special character
×
If other than the valid
character, ‘A4E01’ is
returned.
If the name does not exist in
the memory, ‘A3’ is
returned.
1) -2
D0XnnnnnnYnnnnnnHnnnnnn
1 2 3
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1
PCB dimension
X
6 0 to 999999
×
Only + direction
µm
2
PCB dimension
Y
6 0 to 999999
×
Only + direction
µm
3
Reference hole
pitch
6 0 to 999999
×
Only + direction
µm
AVK3
HOST COMPUTER SYSTEM
3.3 Uploading P.C.B. Data
D77HEC-53-030-A1
3.3-2
Protocol
Condition
Valid in ONLINE mode only.
If a program which does not exist in the memory is specified, ‘A3’ is returned.
After receiving ‘A2’ from HOST, the processing ends.
Start of upload
Host computer
Sends out PCB data.
AVK3
D 0 PCB data
A 0
C1C Program name
D 0
Requests next data.
A 0
Sends out EOP data.
A 2
End of transmission
End of reception