2.1.4 Feeder Settings
All component’s allocation should be operated in this interface, such as selection of nozzles and feeders, pick-up
position, alignment methods, etc.
2.1.4.1. Feeder Arrangement
Left feeders (Feeder 1-25; Right feeders (Feeder 26-45). Special feeders (Feeder 46-55).
There are two ways to setup feeders.
1) Before installing tape& reels.
Press “Allocate chip to feeder”, it will calculate how many different components according to chip list, and
automatically allocate them to each feeder in sequence.
2) After installed tape& reels.
Click on each feeder, it will pop out a drop-down list with all components’ specification, select one by one
according to actual allocation.
2.1.4.2. Feeder Configuration
Select one feeder and tick the item “Apply”, all configuration will be active under this feeder, now user can do
amendment. There’re 3 items: Nozzle information, Feed-box information, Feeder basic information.
One item will be always locked for Feed-box information(Tray feeder information),according to the differences of
components. Operation sequence: Feed-box information(Tray feeder information)---Feeder basic
information---Nozzle information. “Exchange” in Feeder basic information could be used if wrong tape was
placed.

18
Feed-box Information Setting
Function: Adjust the feed rate of needle.
1) Feed rate: It's the distance between two adjacent holes' centers on tape. You can change the needle feeding
rate by change this value
2) Feed speed: Adjust speed by changing its value against different components. Default value is 1.
3) Feed test: After finishing above steps, user can click this item to test component feeding location.
Tray Feeder Information
Function: Use to set the component’s info from tray and tube package. Complete picking up operation under
special feeders by changing the values.
1) Rows: Component qty in each row (X-direction).
2) Columns: Component qty in each column (Y-direction).
3) Right top X/Y: Find the position of right top component by align. Generally it is the last component in IC
tray, and left bottom side is the first component in IC tray.
4) Start X/Y: This is used to define the position of 1
st
component, its default setting is X1, Y1 (that is to say 1
st
row, 1
st
column ). If some IC on the tray has been used, you can directly setting the start X/Y as actual

19
situation, such as the actual 1
st
component is in 2
nd
row, 1
st
column, then type into X2, Y1.
Feeder Basic Information:
1) Firstly click the “Align” under “Position” function, camera will lock the component position on the feeder,
once the modification saved, Pick X/Y data will automatically change to the ones after alignment.
2) Angle: default is 0 degree, support to modify the value to change the mounting angles for wholly feeder.
3) Placement speed: Control the placement speed under this feeder.
4) Footprint: Select corresponding footprint, and in vision alignment, system will take reference of the values in
Footprint Library.
5) Vision: 2 ways as choice against actual need---No action, Jointly .
6) Pick height: control the placement height by dragging the sideward slider.
7) Place height: Set the value according to the exact component thickness.
8) Placement/Pick delay: set a little or 0 both ok.