10 Component handling User Manual S-23 H M 10.6 Component table, mobile Software V ersion SR.405.xx 05/ 99 Issue 368 10.6.3 Docking the component t able W ARNING 10 Check tha t the plac ement he ad is outside t he ran ge…

User Manual S-23 HM 10 Component handling
Software Version SR.405.xx 05/99 Issue 10.6 Component table, mobile
367
Key to Fig. 10.6 - 2
(1) Communication interface connector
(2) Power supply connector for the component table
(3) Compressed air connection
(4) Component table bed
(5) Button for raising and lowering the component table bed
(6) Actuating tube
(7) Fold-down bracket
(8) Holes for the centering pins
(9) Centering pins
(10) Contact surfaces for the slide rails of the component table
(11) Horizontal tensioners
È Click on the STOP PROCESSING PCB icon in the MAIN VIEW menu.
È The PCB in progress will be completed. The icons of the SINGLE FUNCTIONS menu will then
be activated.
È Click on the desired SINGLE FUNCTIONS GANTRY X icon (gantry 1 or 2).
È Click on the GANTRY FUNCTIONS icon.
È From this menu, click on the GO TO SET-UP POSITION button.
È The selected placement head will move across the PCB transport to prevent it being damaged
when the component table is changed.
È Open protective cover of the selected gantry.
È Open the side screens.
È Open the horizontal tensioners (item 11)
È Pull the two actuating tubes (item 6) towards you at the same time and lift up the bracket (item
7) to lock the raised component table bed in its top end position.
È Hold down the button (item 5) for raising the component table bed (item 4) until the component
table bed reaches its top end position.
È Unplug the component table power cable (item 2).
È Unplug the component table control cable (item 1).
È Disconnect the compressed air supply (item 3).
È Remove the component table.

10 Component handling User Manual S-23 HM
10.6 Component table, mobile Software Version SR.405.xx 05/99 Issue
368
10.6.3 Docking the component table
WARNING 10
Check that the placement head is outside the range of the component table. 10
CAUTION 10
When docking the component table, ensure that the table bed is in its top end position and the
bracket (item 7) is folded up. 10
È Cut off the empty tapes for the feeder modules.
È Make sure that the contact surface (item 10) for the component table bed is clean.
È CAREFULLY push the component table into the placement system.
È Connect the compressed air supply (item 3).
È Plug in the control cable (item 1).
È Plug in the power cable (item 2) for the component table.
È Pull the two actuating tubes (item 6) towards you at the same time and then lower the bracket
(item 7) in order to be able to lower the component table bed.
È Check that the centring holes in the component table bed lie precisely over the centering pins
of the placement system.
È Hold down the button (item 5) until the component table bed reaches its top end position.
È Release the button and the component table bed will descend.
È Ensure that the centring pins engage in the centring holes in the component table bed and that
the component table bed is fully lowered.
È Fold up the bracket (item 7) of the component table.
È Lock the two horizontal tensioners (item 11).
È Close the side screens and protective cover.
È Press the Start button to start the placement system.
10
10
10

User Manual S-23 HM 11 Station extensions / options
Software Version SR.405.xx 05/99 Issue 11.1 Nozzle changer
369
11 Station extensions / options
11.1 Nozzle changer
11.1.1 Overview
The placement system is supplied as standard with two revolver heads. As an option, a nozzle
changer can be installed for each revolver head. 11
The nozzle changer consists of at least one, and up to seven magazines, each with twelve nozzle
garages (see Fig. 11.1 - 1). The magazines are seated on a common support and each magazine
is centered using two parallel pins and fixed in place with a screw. 11
11.1.2 Technical data
11
Nozzle changer for the revolver head
Dimensions (length x width x height) 560 mm x 60 mm x 46 mm
Number of nozzle garages Min. 12 / max. 84
Nozzle types 9xx
Time required to open and close the locking plate < 200 ms
Capacity of the reject box Approx. 50 nozzles
Pneumatic circuit Compressed air line 5.3 bar