Error Code Display A Display B 3. T rouble Shooting after Error Display 0005-002 2-61 Tg0248-PM-ER 09 03 01 ZA1-AXIS DA T A RECEIVED VERSION NUMBER FROM STEPPING MOTOR DRIVER W AS INCORRECT . (Cause 1) This is the device…

100%1 / 308
(Cause 1) Is there any dust etc. on the LB2-axis level detection (1) sensor (BPH127) (E / NR
condition) which monitors that the head up / down-axis (LB2) is lifted to the specified
height when the beam B is moved using the lower path line?
If so, completely remove it.
(Cause 2) Is there a large plus figure input in the beam B head 1 up / down column at the “DE-
VICE OFFSET” display?
If it has changed or corrected, correct adjustment is required.
(Cause 3) Is the installation of the LB2-axis level detection (1) sensor (BPH127) loosened or
deviated?
(Reset Procedure in the case of Causes 1, 2, and 3)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the “ZERO” button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
08 06 05 LB2-AXIS INTERLOCK P.C.B. TRANSFER LEVEL VIOLATION WAS DE-
TECTED ON BEAM B.M(B2)-BPH127 E / NR
Error Code Display A Display B
0005-002 2-60 Tg0248-PM-ER
3. Trouble Shooting after Error Display
(Cause 1) Is there any dust etc. on the LB2-axis level detection (1) sensor (BPH126) (E / NR
condition) which monitors that the head up / down-axis (LB2) is lifted to the specified
height when the beam B is moved using the lower path line?
If so, completely remove it.
(Cause 2) Is there a large plus figure input in the beam B head 1 up / down column at the “DE-
VICE OFFSET” display?
If it has changed or corrected, correct adjustment is required.
(Cause 3) Is the installation of the LB2-axis level detection (1) sensor (BPH126) loosened or
deviated?
(Reset Procedure in the case of Causes 1, 2, and 3)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
08 06 04 LB2-AXIS INTERLOCK P.C.B. TRANSFER LEVEL VIOLATION WAS DE-
TECTED ON BEAM B.M(B2)-BPH126 E / NR
Error Code Display A Display B
3. Trouble Shooting after Error Display
0005-002 2-61 Tg0248-PM-ER
09 03 01 ZA1-AXIS DATA RECEIVED VERSION NUMBER FROM STEPPING
MOTOR DRIVER WAS INCORRECT.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
09 01 03 ZA1-AXIS ORIGIN ORIGIN IS NOT SET FOR THIS AXIS.
ZEROING IS REQUIRED.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
09 01 10 ZA1-AXIS ORIGIN ZEROING NOT COMPLETED WITHIN SPECIFIED
TIME.
09 01 02 ZA1-AXIS ORIGIN ORIGIN WAS NOT DETECTED.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
09 01 01 ZA1-AXIS ORIGIN EXCITATION-MONITOR SIGNAL FROM STEPPING
MOTOR DRIVER WAS NOT DETECTED.
(Cause 1) This error occurs when the sensor optical beam is always in E / NR condition or in E /
R condition while all axes are zeroed.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [RESET] button to cancel the error indication.
(2) Check whether the light bean is always E / NR or E / R due to dirt on the sensor, or whether
the sensor is defective.
How to check is to shine the light beam of the sensor on a piece of paper and check whether it
is E / R or E / NR.
Error Code Display A Display B
09 03 02 ZA1-AXIS DATA RECEIVED ADDRESS FROM STEPPING MOTOR
DRIVER WAS INCORRECT.
0005-002 2-62 Tg0248-PM-ER
3. Trouble Shooting after Error Display
08 04 02 ZA1-AXIS COMMUNICATION ERROR OCCURRED IN STEPPING MOTOR DRIVER.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
09 03 03 ZA1-AXIS DATA CHECK SUM ERROR ON RECEIVED DATA FROM
STEPPING MOTOR DRIVER WAS DETECTED.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
09 04 01 ZA1-AXIS COMMUNICATION STEPPING MOTOR DRIVER COULD NOT EXECUTE
RECEIVED COMMAND.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.