3OM-1064-001.pdf - 第231页
Notes : ( a) When the front-lighting system is used to recognize square and deform components, the word “LEAD” is changed to “ELECTRICAL CONT ACT”. (b) The last two digits of the error code represents the lead No. (Cause…

2010X003 COMPONENT OUTWARD
LENGTH ERROR
Note: X represents “1 through 4,
8 and 9”.
COMPONENT OUTWARD LENGTH Y WAS LESS THAN
TOLERANCE.
2010X004 COMPONENT OUTWARD
LENGTH ERROR
Note: X represents “1 through 4,
8 and 9”.
COMPONENT OUTWARD LENGTH Y WAS MORE THAN
TOLERANCE.
2010X005 COMPONENT OUTWARD
LENGTH ERROR
Note: X represents “1 through 4,
8 and 9”.
COMPONENT OUTWARD LENGTH X WAS INCOR-
RECT.
2010X002 COMPONENT OUTWARD
LENGTH ERROR
Note: X represents “1 through 4,
8 and 9”.
COMPONENT OUTWARD LENGTH X WAS MORE THAN
TOLERANCE.
2010X001 COMPONENT OUTWARD
LENGTH ERROR
Note: X represents “1 through 4,
8 and 9”.
COMPONENT OUTWARD LENGTH X WAS LESS THAN
TOLERANCE.
2010X007 COMPONENT OUTWARD
LENGTH ERROR
Note: X represents “1 through 4,
8 and 9”.
COMPONENT OUTWARD LENGTH X OR Y WAS IN-
CORRECT.
2010X006 COMPONENT OUTWARD
LENGTH ERROR
Note: X represents “1 through 4,
8 and 9”.
COMPONENT OUTWARD LENGTH Y WAS INCOR-
RECT.
(Cause 1) Wrong parameters (mold size X, Y and tolerance) are set for the selected component.
(Cause 2) Dirt and dust, etc., have adhered to the nozzle diffusion plate and the head lighting unit
in the vicinity of the corners (or edges or leads).
(Cause 3) An improper parameter is set in the "DIRECTION" data box of the label "LEAD
DATA".
(Reset Procedure in the case of Causes 1, 2 and 3)
Reset Procedure
(1) Check the selected component and the parameters set in the “X” and “Y” text boxes of the
label “MOLD SIZE” and in the “X” and “Y” text boxes of the label “MOLD SIZE TOLER-
ANCE” in the component library data.
(2) If wrong parameters are set in the component library data, correct them.
0103-003 4-34 Tg0248-PM-ER
5. Component Recognition Error Code and List of Error Messages
Error Code Display A Display B
X
Y
Y

Notes:(a) When the front-lighting system is used to recognize square and deform components, the
word “LEAD” is changed to “ELECTRICAL CONTACT”.
(b) The last two digits of the error code represents the lead No.
(Cause 1) The lead width of the selected component exceeds its tolerance.
(Cause 2) Too small parameter is set in the "LEAD WIDTH TOL" data box.
The parameter set in the "LEAD WIDTH TOL" data box becomes valid only when
"MANUAL" is set in both "RECOG DATA SET" and "LEAD WIDTH TOL SET" data
boxes.
(Cause 3) Dirt and dust, etc., have adhered to the nozzle diffusion plate and the head lighting unit
in the vicinity of the leads.
(Reset Procedure in the case of Causes 1, 2 and 3)
Reset Procedure
(1) Check the selected component and the parameters set in the “WIDTH” text boxes of the lebel
“LEAD DATA” in the component library data.
(2) If wrong parameters are set in the component library data, correct them.
5. Component Recognition Error Code and List of Error Messages
0103-003 4-35 Tg0248-PM-ER
20113230 LEAD WIDTH ERROR
to 239
WIDTH OF LEAD 3 (LEFT) EXCEEDS THE TOLERANCE.
Error Code Display A Display B
20113310 LEAD WIDTH ERROR
to 319
WIDTH OF LEAD 1 (LOWER) EXCEEDS THE TOLER-
ANCE.
20113330 LEAD WIDTH ERROR
to 339
WIDTH OF LEAD 3 (LOWER) EXCEEDS THE TOLER-
ANCE.
20113410 LEAD WIDTH ERROR
to 419
WIDTH OF LEAD 1 (RIGHT) EXCEEDS THE TOLER-
ANCE.
20113420 LEAD WIDTH ERROR
to 429
WIDTH OF LEAD 2 (RIGHT) EXCEEDS THE TOLER-
ANCE.
20113320 LEAD WIDTH ERROR
to 329
WIDTH OF LEAD 2 (LOWER) EXCEEDS THE TOLER-
ANCE.
20113430 LEAD WIDTH ERROR
to 439
WIDTH OF LEAD 3 (RIGHT) EXCEEDS THE TOLER-
ANCE.
20113130 LEAD WIDTH ERROR
to 139
WIDTH OF LEAD 3 (UPPER) EXCEEDS THE TOLER-
ANCE.
20113210 LEAD WIDTH ERROR
to 219
WIDTH OF LEAD 1 (LEFT) EXCEEDS THE TOLERANCE.
20113120 LEAD WIDTH ERROR
to 129
WIDTH OF LEAD 2 (UPPER) EXCEEDS THE TOLER-
ANCE.
20113110 LEAD WIDTH ERROR
to 119
WIDTH OF LEAD 1 (UPPER) EXCEEDS THE TOLER-
ANCE.
20113220 LEAD WIDTH ERROR
to 229
WIDTH OF LEAD 2 (LEFT) EXCEEDS THE TOLERANCE.
Lead Width

5. Component Recognition Error Code and List of Error Messages
0103-003 4-36 Tg0248-PM-ER
Error Code Display A Display B
20123001 LEAD PITCH ERROR
to 009
PITCH OF DETECT LEADS EXCEEDS THE TOLER-
ANCE.
(Cause 1) Wrong parameters (lead (electrical contact) pitch) are set for the selected component.
(Cause 2) Too small parameters are set in the "X" and "Y" data boxes of the label "LEAD-TO-
LEAD TOL".
The parameter set in the "LEAD-TO-LEAD TOL" data box becomes valid only when
"MANUAL" is set in both "RECOG DATA SET" and "LEAD-TO-LEAD TOL SET"
data boxes.
(Cause 3) Dirt and dust, etc., have adhered to the nozzle diffusion plate and the head lighting unit
in the vicinity of the leads.
(Reset Procedure in the case of Causes 1, 2 and 3)
Reset Procedure
(1) Check the selected component and the parameters set in the “PITCH” text box of the label
“LEAD (ELECTC.) DATA” in the component library data.
(2) If wrong parameters are set in the component library data, correct them.