3OM-1064-001.pdf - 第158页

0005-002 2-103 Tg0248-PM-ER Error Code Display A Display B 3. T rouble Shooting after Error Display 62 09 10 R-CONVEYOR P .C.B. DETEC- TION P . C.B. XFR. FROM P-CNVR. WERE DISCONTINUED BEFORE P .C.B. XFR. ACT . COMPLETED…

100%1 / 308
0005-002 2-102 Tg0248-PM-ER
Error Code Display A Display B
3. Trouble Shooting after Error Display
62 09 09 R-CONVEYOR P.C.B. DETEC-
TION
P.C.B. XFR. TO P-CNVR. WERE DISCONTINUED
BEFORE P.C.B. XFR. ACT. COMPLETED.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Check whether or not P.C.B. is hanging over on R-conveyor.
Check whether or not P.C.B. transfer error occurs at P-conveyor.
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can’t be re-started, contact our service personnel.
62 09 08 R-CONVEYOR P.C.B. DETEC-
TION
P.C.B. XFR. FROM ER-CNVR. WERE DISCONTINUED
BEFORE P.C.B. REACHED R-CONVEYOR.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Check whether or not P.C.B. is hanging over on R-conveyor.
Check whether or not P.C.B. transfer error occurs at ER-conveyor.
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can’t be re-started, contact our service personnel.
62 09 06 R-CONVEYOR P.C.B. DETEC-
TION
P.C.B. WAS TAKEN ON R-CONVEYOR.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Remove incorrect positioning P.C.B. on R-conveyor.
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can’t be re-started, contact our service personnel.
62 09 07 R-CONVEYOR P.C.B. DETEC-
TION
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Causes 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Check whether or not P.C.B. has dropped from R-conveyor.
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can’t be re-started, contact our service personnel.
P.C.B. REMOVED FROM R-CONVEYOR.
0005-002 2-103 Tg0248-PM-ER
Error Code Display A Display B
3. Trouble Shooting after Error Display
62 09 10 R-CONVEYOR P.C.B. DETEC-
TION
P.C.B. XFR. FROM P-CNVR. WERE DISCONTINUED
BEFORE P.C.B. XFR. ACT. COMPLETED.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Check whether or not P.C.B. is hanging over on R-conveyor.
Check whether or not P.C.B. transfer error occurs at P-conveyor.
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can’t be re-started, contact our service personnel.
Error Code Display A Display B
0005-002 2-104 Tg0248-PM-ER
3. Trouble Shooting after Error Display
63 01 06 CONTROL BOARD INTERLOCK ERROR WAS DETECTED. PRESS THE
[SYS CLR] BUTTON.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
63 01 05 CONTROL BOARD INTERLOCK ERROR WAS DETECTED. PLEASE RE-
START.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
63 01 04 CONTROL BOARD FAILURE IN COMMUNICATION WITH TOUCH
SCREEN CONTROLLER.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
63 01 03 CONTROL BOARD LOW BATTERY VOLTAGE OF MEMORY BOARD WAS
DETECTED.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
63 01 01 CONTROL BOARD LOW BATTERY VOLTAGE OF CALENDAR IC ON CPU
1 BOARD WAS DETECTED.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.