3OM-1064-001.pdf - 第232页

5. Component Recognition Error Code and List of Error Messages 0103-003 4-36 Tg0248-PM-ER Error Code Display A Display B 20123001 LEAD PITCH ERROR to 009 PITCH OF DETECT LEADS EXCEEDS THE TOLER- ANCE. (Cause 1) Wrong par…

100%1 / 308
Notes:(a) When the front-lighting system is used to recognize square and deform components, the
word “LEAD” is changed to “ELECTRICAL CONTACT”.
(b) The last two digits of the error code represents the lead No.
(Cause 1) The lead width of the selected component exceeds its tolerance.
(Cause 2) Too small parameter is set in the "LEAD WIDTH TOL" data box.
The parameter set in the "LEAD WIDTH TOL" data box becomes valid only when
"MANUAL" is set in both "RECOG DATA SET" and "LEAD WIDTH TOL SET" data
boxes.
(Cause 3) Dirt and dust, etc., have adhered to the nozzle diffusion plate and the head lighting unit
in the vicinity of the leads.
(Reset Procedure in the case of Causes 1, 2 and 3)
Reset Procedure
(1) Check the selected component and the parameters set in the “WIDTH” text boxes of the lebel
“LEAD DATA” in the component library data.
(2) If wrong parameters are set in the component library data, correct them.
5. Component Recognition Error Code and List of Error Messages
0103-003 4-35 Tg0248-PM-ER
20113230 LEAD WIDTH ERROR
to 239
WIDTH OF LEAD 3 (LEFT) EXCEEDS THE TOLERANCE.
Error Code Display A Display B
20113310 LEAD WIDTH ERROR
to 319
WIDTH OF LEAD 1 (LOWER) EXCEEDS THE TOLER-
ANCE.
20113330 LEAD WIDTH ERROR
to 339
WIDTH OF LEAD 3 (LOWER) EXCEEDS THE TOLER-
ANCE.
20113410 LEAD WIDTH ERROR
to 419
WIDTH OF LEAD 1 (RIGHT) EXCEEDS THE TOLER-
ANCE.
20113420 LEAD WIDTH ERROR
to 429
WIDTH OF LEAD 2 (RIGHT) EXCEEDS THE TOLER-
ANCE.
20113320 LEAD WIDTH ERROR
to 329
WIDTH OF LEAD 2 (LOWER) EXCEEDS THE TOLER-
ANCE.
20113430 LEAD WIDTH ERROR
to 439
WIDTH OF LEAD 3 (RIGHT) EXCEEDS THE TOLER-
ANCE.
20113130 LEAD WIDTH ERROR
to 139
WIDTH OF LEAD 3 (UPPER) EXCEEDS THE TOLER-
ANCE.
20113210 LEAD WIDTH ERROR
to 219
WIDTH OF LEAD 1 (LEFT) EXCEEDS THE TOLERANCE.
20113120 LEAD WIDTH ERROR
to 129
WIDTH OF LEAD 2 (UPPER) EXCEEDS THE TOLER-
ANCE.
20113110 LEAD WIDTH ERROR
to 119
WIDTH OF LEAD 1 (UPPER) EXCEEDS THE TOLER-
ANCE.
20113220 LEAD WIDTH ERROR
to 229
WIDTH OF LEAD 2 (LEFT) EXCEEDS THE TOLERANCE.
Lead Width
5. Component Recognition Error Code and List of Error Messages
0103-003 4-36 Tg0248-PM-ER
Error Code Display A Display B
20123001 LEAD PITCH ERROR
to 009
PITCH OF DETECT LEADS EXCEEDS THE TOLER-
ANCE.
(Cause 1) Wrong parameters (lead (electrical contact) pitch) are set for the selected component.
(Cause 2) Too small parameters are set in the "X" and "Y" data boxes of the label "LEAD-TO-
LEAD TOL".
The parameter set in the "LEAD-TO-LEAD TOL" data box becomes valid only when
"MANUAL" is set in both "RECOG DATA SET" and "LEAD-TO-LEAD TOL SET"
data boxes.
(Cause 3) Dirt and dust, etc., have adhered to the nozzle diffusion plate and the head lighting unit
in the vicinity of the leads.
(Reset Procedure in the case of Causes 1, 2 and 3)
Reset Procedure
(1) Check the selected component and the parameters set in the “PITCH” text box of the label
“LEAD (ELECTC.) DATA” in the component library data.
(2) If wrong parameters are set in the component library data, correct them.
5. Component Recognition Error Code and List of Error Messages
Error Code Display A Display B
2021A110 ELECTRICAL CONTACT SIZE
to 119 ERROR
Note: A represents “2” or “3”.
WIDTH OF ELECTRICAL CONTACT 1 (UPPER) EX-
CEEDS THE TOLERANCE.
2021A120 ELECTRICAL CONTACT SIZE
to 129 ERROR
Note: A represents “2” or “3”.
WIDTH OF ELECTRICAL CONTACT 2 (UPPER) EX-
CEEDS THE TOLERANCE.
2021A210 ELECTRICAL CONTACT SIZE
to 219 ERROR
Note: A represents “2” or “3”.
WIDTH OF ELECTRICAL CONTACT 1 (LEFT) EXCEEDS
THE TOLERANCE.
2021A220 ELECTRICAL CONTACT SIZE
to 229 ERROR
Note: A represents “2” or “3”.
WIDTH OF ELECTRICAL CONTACT 2 (LEFT) EXCEEDS
THE TOLERANCE.
2021A230 ELECTRICAL CONTACT SIZE
to 239 ERROR
Note: A represents “2” or “3”.
WIDTH OF ELECTRICAL CONTACT 3 (LEFT) EXCEEDS
THE TOLERANCE.
2021A130 ELECTRICAL CONTACT SIZE
to 139 ERROR
Note: A represents “2” or “3”.
WIDTH OF ELECTRICAL CONTACT 3 (UPPER) EX-
CEEDS THE TOLERANCE.
2021A310 ELECTRICAL CONTACT SIZE
to 319 ERROR
Note: A represents “2” or “3”.
WIDTH OF ELECTRICAL CONTACT 1 (LOWER) EX-
CEEDS THE TOLERANCE.
2021A320 ELECTRICAL CONTACT SIZE
to 329 ERROR
Note: A represents “2” or “3”.
2021A410 ELECTRICAL CONTACT SIZE
to 419 ERROR
Note: A represents “2” or “3”.
WIDTH OF ELECTRICAL CONTACT 1 (RIGHT) EX-
CEEDS THE TOLERANCE.
2021A420 ELECTRICAL CONTACT SIZE
to 429 ERROR
Note: A represents “2” or “3”.
WIDTH OF ELECTRICAL CONTACT 2 (RIGHT) EX-
CEEDS THE TOLERANCE.
WIDTH OF ELECTRICAL CONTACT 3 (RIGHT) EX-
CEEDS THE TOLERANCE.
2021A330 ELECTRICAL CONTACT SIZE
to 339 ERROR
Note: A represents “2” or “3”.
WIDTH OF ELECTRICAL CONTACT 3 (LOWER) EX-
CEEDS THE TOLERANCE.
2021A430 ELECTRICAL CONTACT SIZE
to 439 ERROR
Note: A represents “2” or “3”.
(Cause 1) Is the electrical contact size data on the component library correct?
(It can be checked in the component recognition test).
(Cause 2) Is the Electrical Contact Size Tolerance too small?
The Electrical Contact Size Tolerance becomes valid only when the “Recognition
Data” and “Electrical Contact Size Tolerance” are set manually.
(Cause 3) Is there any improper electric contact in the electric contact array?
(Reset Procedure in the case of Causes 1, 2 and 3)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.
WIDTH OF ELECTRICAL CONTACT 2 (LOWER) EX-
CEEDS THE TOLERANCE.
0103-003 4-37 Tg0248-PM-ER