3OM-1064-001.pdf - 第74页

Error Code Display A Display B 0005-002 2-31 Tg0248-PM-ER 3. T rouble Shooting after Error Display 05 03 01 LA1-AXIS DA T A T ARGET LOCA TION V ALUE IS OUT OF RANGE. (Cause 1) This is the device's self-diagnostic me…

100%1 / 308
05 01 05 LA1-AXIS ORIGIN ORIGIN IS NOT SET FOR THIS AXIS.
ZEROING IS REQUIRED.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
05 01 06 LA1-AXIS ORIGIN THE AXIS WAS NOT AT ORIGIN.
05 01 10 LA1-AXIS ORIGIN ZEROING NOT COMPLETED WITHIN SPECIFIED
TIME.
3. Trouble Shooting after Error Display
Error Code Display A Display B
0005-002 2-30 Tg0248-PM-ER
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
Error Code Display A Display B
0005-002 2-31 Tg0248-PM-ER
3. Trouble Shooting after Error Display
05 03 01 LA1-AXIS DATA TARGET LOCATION VALUE IS OUT OF RANGE.
(Cause 1) This is the device's self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
05 02 01 LA1-AXIS TIMING PREVIOUS TASK WAS NOT COMPLETED.
UNABLE TO CONTINUE.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
05 01 11 LA1-AXIS ORIGIN LIMIT SENSOR (+)/() MIGHT BE DEFECTIVE.
(Cause 1) It may run away due to noise or overcurrent.
(Cause 2) The sensor may be defective.
(Reset Procedure in the case of Causes 1 and 2)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
05 04 01 LA1-AXIS LIMIT LIMIT ERROR (+) IS DETECTED.;C(A1)-BPH122 E/NR
05 04 02 LA1-AXIS LIMIT LIMIT ERROR () IS DETECTED.;C(A1)-BPH123 E/NR
(Cause 1) It may run away due to noise or overcurrent.
(Cause 2) The sensor may be defective.
(Reset Procedure in the case of Causes 1 and 2)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
Error Code Display A Display B
0005-002 2-32 Tg0248-PM-ER
3. Trouble Shooting after Error Display
05 05 02 LA1-AXIS SERVOMOTOR
DRIVER
OVERCURRENT WAS DETECTED.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
05 05 01 LA1-AXIS SERVOMOTOR
DRIVER
ABNORMAL DATA SETTING WAS DETECTED.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
05 05 03 LA1-AXIS SERVOMOTOR
DRIVER
FUSE BLEW.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
05 05 04 LA1-AXIS SERVOMOTOR
DRIVER
POSITIONING PULSE OVERFLOW WAS DETECTED.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.