CM88Maintenace2x.PDF.pdf - 第26页

Page 2-26 Machine Maintenance 2-2-4 Head Maintenance Removing and setting heads during cleaning and changing them are supported, and machine parameter required after operation is automatically carried out. Carry out the …

100%1 / 114
Page 2-25
MACHINE PARAMETER
2
Machine Maintenance
Version history
The update history of machine and recognition system software are displayed.
Machine or recognition system software is displayed on the blank for item, and the date of update
and version number are displayed in descending order.
3Y3C-E-MMD02-A01-03
Page 2-26
Machine Maintenance
2-2-4 Head Maintenance
Removing and setting heads during cleaning and changing them are supported, and machine
parameter required after operation is automatically carried out.
Carry out the operation according to directions.
<Removing and Setting Heads>
Head rotate
The transfer head at the pickup side (station 12, 1, and 2) of main axis rotates by 180degrees.
Use this for removing and setting nozzles before removing and setting heads.
Head exchange
Turn off the servo switch, and remove and set the transfer heads.
Main axis step
Use this to move the next head to the position for removing and setting (station 12, 1, and 2).
Main axis rotates by one head (one station).
Head exchange teach
Machine parameter teaching required after setting head is automatically carried out in following
order.
Head angle origin Head rotate center Height sensor angle origin Nozzle height
Nozl set chk
In removing and setting transfer heads, it is necessary to remove and set nozzles.
After setting the nozzle, the machine automatically checks that each nozzle is properly set to the
appropriate position.
3Y3C-E-MMD02-A01-02
Page 2-27
MACHINE PARAMETER
2
Machine Maintenance
2-2-5 Nozzle Maintenance
Removing and setting heads during cleaning and changing them are supported, and machine
parameter teach required after operation is automatically carried out.
Carry out the operation according to directions.
<Removing and Setting Nozzles>
Nozzle select
Nozzle to be cleaned and changed is selected.
Nozzle Extend
The selected nozzle is extended for all heads, and rotated to the direction easy to remove and
set (outside).
Nozzle remove and set
Turn off the servo switch, and remove and set the nozzle.
Main axis step
Use this to move the nozzle of next head to the position for removing and setting (station 12, 1,
and 2). The main axis rotates by one head (one station).
Nozzle exchange teach
Machine parameter teaching required after setting nozzle is automatically carried out in following
order.
Height sensor angle origin Nozzle height
Nozl set chk
In removing and setting the nozzle, the machine automatically checks that each nozzle is prop-
erly set to the appropriate position.
3Y3C-E-MMD02-A01-00