00195094-0202-MM-D3_EN.pdf - 第24页

6 Weekly maintenance jobs SIPLACE D3 08/2008 US Edition 24 6 W eekly maintenance jobs 6

100%1 / 98
SIPLACE D3 5 Daily maintenance jobs
08/2008 US Edition
23
Vacuum the feeder modules 5
5
Keep at least 1 cm away from the feeder module to avoid damaging the component covers. 5
5
a Carefully clean the feeder area with a vacuum cleaner.
There should be no loose components in the feeder area.
5
: Close the protective cover.
: Press the Start button.
5
The placement machine can continue placement during the next steps. 5
5
5
5
Empty waste tape container 5
s Pull the waste tape co
ntainer out of the component trolley.
d Empty it into the waste bin.
5
When you pull out the waste container, hold it flat so that none of the waste tape drops out. 5
5
5
Empty the waste container as it fills up with waste. 5
5
5
: Repeat the "daily maintenance jobs" at every feeder area.
5
5
5
5
5
5
6 Weekly maintenance jobs SIPLACE D3
08/2008 US Edition
24
6 Weekly maintenance jobs
6
SIPLACE D3 6 Weekly maintenance jobs
08/2008 US Edition
25
6
6
You will need for the weekly maintenance jobs: 6
Vacuum cleaner (with appropriate nozzle)
Waste bin
–Brush
Scissors
Lint-free cloths
Ethyl alcohol
Set of cleaned ceramic nozzles
or
new plastic nozzles
6
6
There must be no PCBs in the machine during the following maintenance steps. 6
6
: Press the Stop button.
: Open the protective cover.
6
Push the gantry carefully and gently using the handle of the C&P20 head or the bracket of the X-
axis head plate (not the end buffers). 6
6
: Push the gantry over the component table. This will stop it outside your working area.
6
Vacuum the PCB conveyor / lifting table 6
a Use the vacuum cleaner to remove all loose components on and around the PCB conveyor
and th
e lifting table.
Loose components on the PCB conveyor could cause faults. 6
6
6
6
Clean the X/Y scales (as required) 6
6
Always use soft cloths and minimal pressure to clean the scale rods. 6
6
s Clean the incremental scales of the X and Y axes using a lint-free cloth moistened with ethyl
alcohol.
6
Dirty scale rods cause counting errors on the X and Y axes, and thus to machine stoppages. 6
6